Characterisation of a PVCP based tissue-mimicking phantom for Quantitative Photoacoustic Imaging

نویسندگان

  • Martina Fonseca
  • Bajram Zeqiri
  • Paul Beard
  • Ben Cox
چکیده

Photoacoustic imaging can provide high resolution images of tissue structure, pathology and function. As these images can be obtained at multiple wavelengths, quantitatively accurate, spatially resolved, estimates for chromophore concentration, for example, may be obtainable. Such a capability would find a wide range of clinical and pre-clinical applications. However, despite a growing body of theoretical papers on how this might be achieved, there is a noticeable lack of studies providing validated evidence that it can be achieved experimentally, either in vitro or in vivo. Well-defined, versatile and stable phantom materials are essential to assess the accuracy, robustness and applicability of multispectral Quantitative Photoacoustic Imaging (qPAI) algorithms in experimental scenarios. This study assesses the potential of polyvinyl chloride plastisol (PVCP) as a phantom material for qPAI, building on previous work that focussed on using PVCP for quality control. Parameters that might be controlled or tuned to assess the performance of qPAI algorithms were studied: broadband acoustic properties, multiwavelength optical properties with added absorbers and scatterers, and photoacoustic efficiency. The optical and acoustic properties of PVCP can be tuned to be broadly representative of soft tissue. The Grüneisen parameter is larger than expected in tissue, which is an advantage as it increases the signal-to-noise ratio of the photoacoustic measurements. Interestingly, when the absorption was altered by adding absorbers, the absorption spectra measured using high peak power nanosecond-pulsed sources (typical in photoacoustics) were repeatably different from the ones measured using the low power source in the spectrophotometer, indicative of photochemical reactions taking place.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterisation of a phantom for multiwavelength quantitative photoacoustic imaging.

Quantitative photoacoustic imaging (qPAI) has the potential to provide high- resolution in vivo images of chromophore concentration, which may be indicative of tissue function and pathology. Many strategies have been proposed recently for extracting quantitative information, but many have not been experimentally verified. Experimental phantom-based validation studies can be used to test the rob...

متن کامل

Biologically relevant photoacoustic imaging phantoms with tunable optical and acoustic properties.

Established medical imaging technologies such as magnetic resonance imaging and computed tomography rely on well-validated tissue-simulating phantoms for standardized testing of device image quality. The availability of high-quality phantoms for optical-acoustic diagnostics such as photoacoustic tomography (PAT) will facilitate standardization and clinical translation of these emerging approach...

متن کامل

Examination of Contrast Mechanisms in Optoacoustic Imaging of Thermal Lesions

Optoacoustic Imaging is based on the thermal expansion of tissue caused by a temperature rise due to absorption of short laser pulses. At constant laser fluence, optoacoustic image contrast is proportional to differences in optical absorption and the thermoacoustic efficiency, expressed by the Grüneisen parameter, Γ. Γ is proportional to the thermal expansion coefficient, the sound velocity squ...

متن کامل

Use of a pulsed fibre laser as an excitation source for photoacoustic tomography

The use of a pulsed fibre laser as an excitation source for photoacoustic tomography has been investigated. Fibre lasers have the advantage of being compact, robust and efficient compared to traditional excitation sources used for photoacoustic tomography (e.g. Q-switched Nd:YAG pumped OPO or dye systems). Their high pulse repetition frequencies and adjustable pulse duration, shape and duty cyc...

متن کامل

Quantitative photoacoustic imaging: correcting for heterogeneous light fluence distributions using diffuse optical tomography.

The specificity of molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. The PA signal is proportional to the product of the optical absorption coefficient and local light fluence; quantitative PA measurements of the optical absorption coefficient therefore require an accurate estimation of optical fluence. Light-modeling aided ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015