Mechanism for improving the signal-to-noise ratio in scanning optical microscopes.

نویسندگان

  • T D Milster
  • E P Walker
چکیده

We demonstrate an improved signal-to-noise ratio in a scanning optical microscope used to read out information from a magneto-optical data storage layer. By placing a shading band in the return path of the optical system we can reduce noise by as much as 3 dB in certain spatial frequency ranges. The signal-to-noise ratio improvement arises from differences in the signal and noise distributions in the pupil of the optical system. Although the experimental results are shown only in one dimension, the concept is applicable to two-dimensional scanning of low-contrast samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving 3D Reconstruction from STEM Data

The successful implementation of spherical aberration correction in the scanning transmission electron microscope (STEM) is one of the most significant accomplishments in electron optics in the last few decades. Correction of magnetic lens aberrations to the third order has led to significant improvements in point resolution and signal-to-noise ratio, expanding the range of accessible lattice s...

متن کامل

A Versatile , Stable Scanning Proximal Probe Microscope

We present a novel scanning proximal probe microscope design utilizing a piezo-electric driven coarse positioning mechanism in x, y, and z, while maintaining relatively small lateral dimensions. The instrument is suitable for insertion into a dewar. The primary purpose of this work is to develop a stable yet versatile instrument in order to meet the signal averaging limitations imposed by low s...

متن کامل

Imaging properties of high aperture multiphoton fluorescence scanning optical microscopes

A theory for multiphoton fluorescence imaging in high aperture scanning optical microscopes employing finite sized detectors is presented. The effect of polarisation of the fluorescent emission on the imaging properties of such microscopes is investigated. The lateral and axial resolutions are calculated for one-, twoand three-photon excitation of p-quaterphenyl for high and low aperture optica...

متن کامل

Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition

Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...

متن کامل

An Efficient Covalent Coating on Glass Slides for Preparation of Optical Oligonucleotide Microarrays

Objective(s): Microarrays are potential analyzing tools for genomics and proteomics researches, which is in needed of suitable substrate for coating and also hybridization of biomolecules.   Materials and Methods: In this research, a thin film of oxidized agarose was prepared on the glass slides which previously coated with poly-L-lysine (PLL). Some of the aldehyde groups of the activated aga...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 21 16  شماره 

صفحات  -

تاریخ انتشار 1996