Comparison of IOL power calculation and refractive outcome after laser refractive cataract surgery with a femtosecond laser versus conventional phacoemulsification.

نویسندگان

  • Tamás Filkorn
  • Illés Kovács
  • Agnes Takács
  • Eva Horváth
  • Michael C Knorz
  • Zoltán Z Nagy
چکیده

PURPOSE To compare intraocular lens (IOL) power calculation and refractive outcome between patients who underwent laser refractive cataract surgery with a femtosecond laser and those with conventional cataract surgery. METHODS In this prospective study, 77 eyes from 77 patients underwent laser refractive cataract surgery (laser group; Alcon LenSx femtosecond laser), and conventional cataract surgery with phacoemulsification was performed in 57 eyes from 57 patients (conventional group). Biometry was done with optical low coherence reflectometry (Lenstar LS900, Haag-Streit AG), and IOL calculation was performed with third-generation IOL formulas (SRK/T, Hoffer Q, and Holladay). The refractive outcome was analyzed using the mean absolute error (MAE; difference between predicted and achieved postoperative spherical equivalent refraction), and multivariable regression analysis was performed to compare the two groups. RESULTS No significant differences were found between age, axial length, keratometry, and preoperative corrected visual acuity in the laser and conventional groups (P>.05; Mann-Whitney U test). At least 6 weeks after surgery, MAE was significantly lower in the laser group (0.38±0.28 diopters [D]) than in the conventional group (0.50±0.38 D) (P=.04). The difference was the greatest in short (axial length <22.0 mm, 0.43±0.41 vs 0.63±0.48) and long (axial length >26.0 mm, 0.33±0.24 vs 0.63±0.42) eyes. CONCLUSIONS Laser refractive cataract surgery with a femtosecond laser resulted in a significantly better predictability of IOL power calculation than conventional phacoemulsification surgery. This difference is possibly due to a more precise capsulorrhexis, resulting in a more stable IOL position.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification

Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...

متن کامل

Comparison of IOL--master and ultrasound biometry in preoperative intra ocular lens (IOL) power calculation.

Postoperative refractive outcome largely depends on the accuracy of calculating power of implanted IOL. Lens power calculation can be done by conventional ultrasound biometry and partial coherence laser interferometry (IOL Master). The aim was to compare the accuracy of IOL power calculations using conventional ultrasound biometry and partial coherence laser interferometry.40 eyes were included...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

Femtosecond laser: the future of cataract surgery?

Cataract surgery techniques have evolved from intracapsular cataract surgery to extracapsular cataract surgery (ECCE) to phacoemulsification, with a progressive decrease in the size of the surgical wound and increased safety and predictability of the surgical procedure. Cataract surgical techniques and intraocular lens (IOL) technologies continue to evolve to provide patients with the optimum p...

متن کامل

Comparison of intraocular lens power calculation methods after myopic laser refractive surgery without previous refractive surgery data.

PURPOSE To compare the accuracy of intraocular lens (IOL) power calculation methods for post-myopic excimer laser surgery patients without previous refractive surgery data using the Holladay IOL Consultant Program and the American Society of Cataract and Refractive Surgery (ASCRS) IOL Power Calculator. SETTING Wang Vision Cataract and LASIK Center, Nashville, Tennessee, USA. DESIGN Case ser...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 28 8  شماره 

صفحات  -

تاریخ انتشار 2012