Incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography after drug-eluting stent implantation.
نویسندگان
چکیده
BACKGROUND We investigated the incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography (OCT) after drug-eluting stent implantation. METHODS AND RESULTS We analyzed the OCT images from 351 patients with 356 lesions who received poststent and follow-up OCT examinations. Acute stent malapposition was observed in 62% of lesions. Approximately half of the acute stent malappositions were located within the edges of the stents. Severe diameter stenosis, calcified lesions, and long stents were independent predictors of acute stent malapposition. Follow-up OCT examinations were performed 175±60 days after drug-eluting stent implantation. Thirty-one percent of lesions with acute stent malapposition remained malapposed (late-persistent stent malapposition) and were typically (72%) located within the edges of the stent. The location within the stent edges and the volume of acute stent malapposition were independent predictors of late-persistent stent malapposition. Acute stent malapposition with a volume >2.56 mm(3) differentiated late-persistent stent malapposition from resolved acute stent malapposition. Late-acquired stent malapposition was detected in 15% of all lesions and was usually (61%) located within the stent body. Late-acquired stent malapposition was more frequently associated with plaque/thrombus prolapse on poststent OCT images (70% versus 42%; P<0.001). Clinical events, including cardiovascular death, nonfatal myocardial infarction, and stent thrombosis, did not occur in patients with late stent malapposition during the follow-up period of 28.6±10.3 months after drug-eluting stent implantation. CONCLUSIONS Acute, late-persistent, and late-acquired stent malapposition had relatively high incidences but different predictors. The clinical outcome of stent malapposition was favorable.
منابع مشابه
Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
OBJECTIVES We performed this study to investigate the vascular response in early period after zotarolimus-eluting stent (ZES) (Endeavor Sprint, Medtronic CardioVascular, Minneapolis, Minnesota) implantation. BACKGROUND The ZES has different characteristics, with biocompatible polymer and rapid drug-elution, compared with the first-generation drug-eluting stents (DES). METHODS The ENDEAVOR O...
متن کاملLate stent malapposition combined by thrombus resolution after primary stenting in acute myocardial infarction: optical coherence tomography findings.
The late stent malapposition (LSM) is defined as a separation of the stent struts from the intima of the coronary artery wall which was not present just after implanting the stent. Although drug-eluting stents (DESs) dramatically reduce the in-stent restenosis, several studies have reported a higher frequency of LSM on follow-up intravascular ultrasound (IVUS) examination after DES implantation...
متن کاملCharacteristics of Earlier Versus Delayed Presentation of Very Late Drug‐Eluting Stent Thrombosis: An Optical Coherence Tomographic Study
BACKGROUND The pathophysiology underlying very late drug-eluting stent (DES) thrombosis is not sufficiently understood. Using optical coherence tomography, we investigated characteristics of very late stent thrombosis (VLST) according to different onset times. METHODS AND RESULTS A total of 98 patients from 10 South Korean hospitals who underwent optical coherence tomography for evaluation of...
متن کاملMechanisms of late stent-related myocardial infarction: insights from optical coherence tomography
This article focuses on optical coherence tomography findings in patients with late major cardiovascular events like myocardial infarction and/or stent thrombosis, following drug-eluting stent and bare-metal stent implantation. Uncovered stent struts and malapposition seem to play a critical role in drug-eluting stent-related late events. Neointimal features similar to native atherosclerosis ar...
متن کاملImpact of Coronary Plaque Characteristics on Late Stent Malapposition after Drug-Eluting Stent Implantation.
PURPOSE To evaluate the impact of pre-procedural coronary plaque composition assessed by virtual histology intravascular ultrasound (VH-IVUS) on late stent malapposition assessed by optical coherence tomography (OCT) following drug-eluting stent (DES) implantation. MATERIALS AND METHODS The study population consisted of 121 patients (121 lesions) who underwent both pre-procedural VH-IVUS and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 7 1 شماره
صفحات -
تاریخ انتشار 2014