Is haemodynamic evaluation with impedance cardiography in patients with heart failure undergoing testing of the implanted cardioverter-defibrillator of clinical importance?

نویسندگان

  • Paweł Krzesiński
  • Dariusz Michałkiewicz
  • Zbigniew Orski
  • Krystian Krzyżanowski
  • Grzegorz Gielerak
چکیده

BACKGROUND Identification of individual factors associated with high defibrillation threshold (DFT) seems to be of high clinical importance. Impedance cardiography (ICG) may be used for non-invasive evaluation of the haemodynamic status. Whether ICG parameters may improve identification of patients with high DFT has not yet been examined. AIM To evaluate clinical risk factors of high DFT including ICG parameters. METHODS The study group included 69 patients with heart failure (aged 62.7 ± 9.5 years, NYHA class: I-III) selected for implantation of a cardioverter-defibrillator (ICD). Clinical assessment included physical examination, echocardiography and ICG monitoring before and after defibrillation. RESULTS Initial defibrillation was unsuccessful in 17 (36.6%) patients. High DFT group was characterised by higher left ventricular end-diastolic diameter (LVEDD ≥ 5.6 cm: 100.0% vs 70.2%; p = 0.01), lower left ventricular ejection fraction (LVEF < 30%: 76.5% vs 44.7%; p = 0.024), higher baseline thoracic fluid content (one of ICG parameters) (TFC ≥ 35 1/kOhm: 29.4% vs 6.4%; p = 0.014) and more frequent amiodarone treatment (41.2% vs 14.9%; p = 0.025). A proposed algorithm based on predefined values of TFC, LVEF and LVEDD was shown to be effective in predicting high DFT (area under curve: 0.771). CONCLUSIONS Risk factors of high DFT include left ventricular enlargement, low LVEF, high TFC and amiodarone treatment. An algorithm including TFC measurement by ICG increases the efficacy of identification of patients with high DFT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary Congestion at Rest and Abnormal Ventilation During Exercise in Chronic Systolic Heart Failure

BACKGROUND In patients with chronic heart failure, abnormal ventilation at cardiopulmonary testing (expressed by minute ventilation-to-carbon dioxide production, or VE/VCO2 slope, and resting end-tidal CO2 pressure) may derive either from abnormal autonomic or chemoreflex regulation or from lung dysfunction induced by pulmonary congestion. The latter hypothesis is supported by measurement of pu...

متن کامل

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Cardiac or Other Implantable Electronic Devices and Sleep-disordered Breathing - Implications for Diagnosis and Therapy.

Sleep-disordered breathing (SDB) is of growing interest in cardiology because SDB is a highly prevalent comorbidity in patients with a variety of cardiovascular diseases. The prevalence of SDB is particularly high in patients with cardiac dysrhythmias and/or heart failure. In this setting, many patients now have implantable cardiac devices, such as pacemakers, implantable cardioverter-defibrill...

متن کامل

کاربرد مدل‌های نیمه‌پارامتری بقا در ارزیابی عوامل خطر وابسته به زمان بر نرخ شوک‌های واردشده به بیماران قلبی

Background: One of the treatments in patients with dangerous diseases particularly heart failure, is Implantable Cardioverter Defibrillator (ICD) that is used to prevent sudden cardiac death. Regarding to the superiority of ICD rather than medical treatment, the purpose of this study is the assessment of time-dependent effective factors on the rates of entered shocks to patients with ICD. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Kardiologia polska

دوره 69 6  شماره 

صفحات  -

تاریخ انتشار 2011