Effect of removal and reinsertion of force-closed stems on deformation of total hip arthroplasty☆
نویسندگان
چکیده
OBJECTIVES This study investigated removal of a force-closed stem, done in order to improve acetabular exposure during revision, with reinsertion afterwards. It is unknown how much this procedure modifies the stem/cement interface. METHODS Three tapered stem models were implanted into composite femurs. Strain gauges were embedded in the medial aspect of the cement mantle and in several positions on the outer surface of the femurs. The deformation was measured during static loading, which was applied at two different times: after implantation and after one million loading cycles, followed by stem removal and reinsertion. The t test was performed. The differences in deformation were compared (at p ≤ 0.05) between the two static loading times and among the three stem designs. RESULTS No significant differences in deformation were found after the two loading times for the three models. No significant differences in the initial deformations of the three models were found for most of the gauges attached to the femurs. CONCLUSIONS Reinsertion of the force-closed stem does not alter the load transmission from the stem to the cement and to the surface of the femur, even after one million loading cycles.
منابع مشابه
Bone density study of the proximal femur after hip arthroplasty with porous-coated implants
Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملEarly subsidence of shape-closed hip arthroplasty stems is associated with late revision. A systematic review and meta-analysis of 24 RSA studies and 56 survival studies.
BACKGROUND AND PURPOSE Few studies have addressed the association between early migration of femoral stems and late aseptic revision in total hip arthroplasty. We performed a meta-regression analysis on 2 parallel systematic reviews and meta-analyses to determine the association between early migration and late aseptic revision of femoral stems. PATIENTS AND METHODS Of the 2 reviews, one cove...
متن کاملA challenge on Orthopedic Sciences: The Influence of Spinal Disease and Deformities on Total Hip Arthroplasty: A Review on Literature
Background: Adult degenerative disorders of hip and spine are common. The recent studies inconsistently havediscussed about the influence of spinal disorders on total hip arthroplasty (THA). In this review, we discussed clearlyabout these relationships and their effects on the most appropriate position of the acetabular component.Methods: We searched on databases and evaluated the articles abou...