Dynamics of adaptation at high luminances: adaptation is faster after luminance decrements than after luminance increments.
نویسندگان
چکیده
As is well known, dark adaptation in the human visual system is much slower than is recovery from darkness. We show that at high photopic luminances the situation is exactly opposite. First, we study detection thresholds for a small light flash, at various delays from decrement and increment steps in background luminance. Light adaptation is nearly complete within 100 ms after luminance decrements but takes much longer after luminance increments. Second, we compare sensitivity after equally visible pulses or steps in the adaptation luminance and find that detectability is initially the same but recovers much faster for pulses than for increment steps. This suggests that, whereas any residual threshold elevation after a step shows the incomplete luminance adaptation, the initial threshold elevation is caused by the temporal contrast of the background steps and pulses. This hypothesis is further substantiated in a third experiment, whereby we show that manipulating the contrast of a transition between luminances affects only the initial part of the threshold curve, and not later stages.
منابع مشابه
Light Adaptation and Early Processing in the Human Visual System
As is well known, dark adaptation in the human visual system is much slower than recovery from darkness. Here we show that at high photopic luminances the situation is exactly opposite. First, we study detection thresholds for a small light flash, at various delays from decrement and increment steps in background luminance. Light adaptation is nearly complete within 100 ms after luminance decre...
متن کاملEffect of eccentricity on luminance-pedestal flicker thresholds
We investigated the effect that spatially coincident luminance increments (luminance pedestals) have on flicker thresholds at several eccentricities and target sizes. Luminance pedestals elevated flicker amplitude-thresholds more when stimuli were presented eccentrically, both at low (4 Hz) and high (20 Hz) temporal frequencies. Altering the size of the eccentric stimulus failed to equate centr...
متن کاملLuminance coding of briefly presented stimuli in area 17 of the rhesus monkey.
1. Single cells in area 17 of the alert rhesus monkey were classified according to their sensitivity to variations in stimulus orientation, color, and direction of movement. The sensitivity of the cells to stimulus luminance was then tested using moving bars and large stationary spots presented for 500 ms. The luminance of the stimulus was varied over trials; background luminance was kept const...
متن کاملColor and luminance detection and discrimination asymmetries and interactions
We investigated the nature of color and luminance processes under threshold and suprathreshold conditions in normal trichromatic observers. Detection and discrimination contours as well as threshold-vs-contrast (Tvc) functions were measured in the Derrington-Krauskopf-Lennie (DKL) color space using a masking paradigm. Such contours revealed substantial threshold asymmetries along the three card...
متن کاملOn the search for an appropriate metric for reaction time to suprathreshold increments and decrements
Weber contrast, DeltaL/L, is a widely used contrast metric for aperiodic stimuli. Zele, Cao & Pokorny [Zele, A. J., Cao, D., & Pokorny, J. (2007). Threshold units: A correct metric for reaction time? Vision Research, 47, 608-611] found that neither Weber contrast nor its transform to detection-threshold units equates human reaction times in response to luminance increments and decrements under ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 14 9 شماره
صفحات -
تاریخ انتشار 1997