A challenging image during pacemaker implantation

نویسندگان

  • Yavuzer Koza
  • Ziya Şimşek
  • Muhammed Hakan Taş
  • Hüseyin Şenocak
چکیده

Answer: p. 91 A 60-year-old female patient was admitted to our hospital with the complaints of syncope and palpitation. She had undergone coronary artery bypass graft surgery 2 years previously and was not taking any medications at the time of presentation. Her electrocardiography on admission was in normal sinus rhythm. Twenty-four-hour Holter monitoring revealed frequent pauses up to 5 seconds with paroxysmal bradycardia and tachycardia episodes. Coronary angiography showed that all coronary grafts (left internal mammarian artery-left anterior descending artery, saphenous vein-right coronary artery) were patent. In view of the Holter findings and the patient’s symptoms, a dualchamber pacemaker implantation was planned. Before the procedure, the patient was well hydrated, and the left subclavian vein was chosen for implantation. Because multiple attempts to puncture the subclavian vein were unsuccessful, a venography was performed and revealed a challenging image (Fig. 1, Video 1). Despite incremental doses of nitroglycerin via the ipsilateral peripheral vein, this image did not change (Fig. 2, Video 2). A last attempt by a lateral approach was than successful with cannulation of the subclavian vein, but there was no good flashback. However, a hydrophilic guidewire was tried, and it was successfully passed through this segment without difficulty. A dual-chamber pacemaker was implanted with no post-procedural event.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

Complete Congenital Heart Block in a Neonatal Lupus Erythematosus Associated with Pulmonary Involvement without Pacemaker Implantation: A Case Report

Background: Neonatal lupus erythematosus is an uncommon disease. Congenital complete heart block (CCHB) usually happens in neonates with maternal systemic lupus erythematosus. The most prevalent presentation of CCHBis bradycardiathatcanbediagnosed through an electrocardiogram. Case report: Here in, we present the case of a full-term male neonate with gestational age of 37 weeks and birth weigh...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

Implantation of Transvenous Permanent Pacemaker in a Patient with Persistent Left Superior Vena Cava and Absent Right Superior Vena Cava

Vascular access has remained a major challenge for implantation of permanent pacemaker leads. A persistent Left Superior Vena Cava (LSVC), especially with an absent Right Superior Vena Cava (RSVC), is a rare finding during pacemaker implantation and is accompanied by technical difficulties. Herein, we describe a case of sinoatrial node arrest, in which finding a suitable vein for passing the le...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015