The ocular pulse amplitude at different intraocular pressure: a prospective study.
نویسندگان
چکیده
PURPOSE To investigate changes in ocular pulse amplitude (OPA) during a short-term increase in intraocular pressure (IOP) and to assess possible influences of biometrical properties of the eye, including central corneal thickness (CCT) and axial length. METHODS In a prospective, single centre study, OPA and IOP as measured by dynamic contour tonometry (DCT) were taken before baseline- and post-OPA (delta) intravitreal injection of 0.05 ml anti-vascular endothelial growth factor agents. Analysis was performed employing linear regression with baseline- and post (delta)-OPA differences as the dependent and post-IOP as well as delta IOP as the independent variable. A multilinear regression analysis with delta OPA as the dependent variable and baseline IOP, post-IOP, CCT and axial length as independent variables was conducted. RESULTS Forty eyes of 40 patients were included. IOP and OPA increased significantly after injection (IOP mean increase ± SD: 17.83 ± 9.83 mmHg, p < 0.001; OPA mean increase ± SD: 1.39 ± 1.16 mmHg, p < 0.001). For every mmHg increase in IOP, the OPA showed a linear increase of 0.05 mmHg (slope 0.05, 95% CI: 0.02-0.09, p = 0.003, r(2) = 0.20). Multiple regression analysis with delta OPA as the dependent variable revealed a partial correlation coefficient of 0.47 (p = 0.003) for post-IOP as the only significant contribution. CONCLUSION A clear positive relationship between OPA measurements and IOP levels was shown in a clinical routine setting using DCT focusing on baseline and postinterventional comparisons of OPA values after intravitreal injections in patients with exudative age related macular degeneration. When considering the OPA for diagnostic purposes, we recommend indication of corresponding IOP values.
منابع مشابه
Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملOphthalmic pulse studies. I. Influence of intraocular pressure.
The relationship of the ophthalmic pulse amplitude to the intraocular pressure has been described in rabbits and dogs. The effect of a suction cup on the intraocular pressure has been investigated in rabbit eyes and human eyes. Sample pulse tracings have been obtained using a suction cup on rabbits and man. Two estimates were made of the volume changes associated with the ophthalmic pulse xoave...
متن کاملDynamic contour tonometry in asymmetric glaucoma patients
BACKGROUND The purpose of this study was to determine any difference in dynamic contour tonometry and ocular pulse amplitude in asymmetric glaucoma patients with the same applanation intraocular pressure. METHODS This is a prospective, observational study of 30 glaucoma patients and 11 controls from June 2007 to February 2008. Most of the glaucoma patients were on prostaglandin analog treatme...
متن کاملThe ocular pulse and intraocular pressure as a screening test for carotid artery stenosis.
The ocular pulse and applanation tension were measured with a recording applanation tonometer in 38 patients suspected of having internal carotid artery stenosis. Abnormalities of the ocular pulse amplitude, intraocular pressure, or combinations of these two measurements were found in 23 (82%) of 28 patients who were subsequently found to have angiographic evidence of 50% or more stenosis of on...
متن کاملCorrelation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes
BACKGROUND The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure...
متن کاملThe influence of sex difference in measurements with the Langham Ocular Blood Flow System.
PURPOSE To assess sex difference and parameters possibly accounting for such a difference in healthy subjects evaluated by means of the Langham Ocular Blood Flow (OBF) System. METHODS Pulse amplitude of intraocular pressure (IOP) and pulsatile ocular blood flow (POBF) as measured with the Langham OBF System were assessed in 86 healthy men and 69 healthy women. RESULTS Compared to men, women...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta ophthalmologica
دوره 89 5 شماره
صفحات -
تاریخ انتشار 2011