In vitro evaluation of laser fluorescence devices for caries detection through stereomicroscopic imaging.

نویسندگان

  • Roxana Oancea
  • Angela Codruţa Podariu
  • Liliana Vasile
  • Ruxandra Sava-Roşianu
  • Roxana Folescu
چکیده

The aims of this study were to determine the diagnostic accuracy and reproducibility of the laser fluorescence device (LF), and the relationship between laser fluorescence readings taken at the entrance of the fissure, ICDAS visual examination caries detection system and the histological depth of the lesion. Two hundred and forty teeth (122 human third molars and 118 bicuspids) were selected from 62 patients enrolled in the study. Visual and LF examinations (Diagnodent, Kavo, Biberach, Germany) of the occlusal surfaces were performed in vivo. After tooth extraction, histological sections were evaluated by stereomicroscopy in vitro. Statistical analysis was performed using multiple statistical methods (SPSS ver. 17). Intra-examiner reproducibility for the LF measurements was excellent: intra-class-correlation coefficient (ICC) for LF was 0.957. Kappa values for each examiner's reproducibility were 0.74-0.82. The diagnostic performance of the LF device gave a good overall diagnostic accuracy according to ICDAS II codes and histological values as indicated by the area under the ROC curve of 0.707 and 0.709 respectively. The results of the study showed acceptable diagnostic accuracy for the laser fluorescence device. This supports the view that dentists can be site specific in applying fluorescence-based devices to multiple discrete sites within the same surface. In conclusion, these diagnostic methods have different characteristics, indications and limitations for use. In order to detect caries on occlusal surfaces thoroughly, a combination of methods would be the best practice moderated by clinical knowledge and experience.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Diagnodent Accuracy in Detecting Approximal Caries in Primary Molars

Introduction: Detection of caries lesions on approximal surfaces of posterior teeth is difficult, since wide contact points hamper direct visual inspection. Due to the importance of the early detection of dental caries, the aim of this study is to compare the performance of different methods (visual, bitewing radiography and DIAGNOdent) in detecting approximal caries in primary molars. Methods:...

متن کامل

Comparative Studies of High Contrast Fluorescence Imaging Efficiency of Silica-coated CdSe Quantum Dots with Green and Red Emission

Herein we report the possibility of using green and red emitting silica-coated cadmium selenide (CdSe) quantum dots (QDs) for remarkable stem and cancer cellular imaging, efficient cellular uptake and fluorescence imaging of semi and ultra-thin sections of tumor for in vivo tumor targeted imaging applications. The comparative studies of high contrast cellular imaging behaviours of the silica-co...

متن کامل

In vitro Comparison of Conventional Film and Direct Digital Radiography in Proximal Caries Detection

Introduction: Various systems for intraoral digital radiography have been available as an alternative to film–based radiography. In consideration of several advantages of digital radiography such as less patient absorbed dose, manipulation of im‌age quality and elimination of processing, it has been extensively used in different fields of denti‌stry in recent years. The purpose of this study wa...

متن کامل

Alternative methods to visual and radiographic examinations for approximal caries detection.

A shift in caries prevalence from occlusal surfaces to approximal surfaces has been demonstrated by epidemiological studies. Two recent meta-analyses evaluated the performance of visual examination and radiography for carious lesion detection, and reported low sensitivity but high specificity for early approximal caries detection. This suggests that the conventional methods have a higher risk o...

متن کامل

Agreement of Bitewing and Digital Panoramic Radiographies in the Detection of Proximal Caries

Background & Aims: Conventional radiography is used for the diagnosis of problems such as dental caries and failure in root canal therapy. The diagnosis accuracy of conventional radiography is acceptable in the evaluation of anatomical and pathological structures. However, it seems that by using digital radiography we can obtain more information in this field. The aim of this study is to compar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie

دوره 54 2  شماره 

صفحات  -

تاریخ انتشار 2013