INTRODUCTION High-quality cardiopulmonary resuscitation (CPR) is critical for successful cardiac arrest outcomes. Mechanical devices may improve CPR quality. We simulated a prehospital cardiac arrest, including patient transport, and compared the performance of the LUCAS™ device, a mechanical chest compression-decompression system, to manual CPR. We hypothesized that because of the movement involved in transporting the patient, LUCAS would provide chest compressions more consistent with high-quality CPR guidelines. METHODS We performed a crossover-controlled study in which a recording mannequin was placed on the second floor of a building. An emergency medical services (EMS) crew responded, defibrillated, and provided either manual or LUCAS CPR. The team transported the mannequin through hallways and down stairs to an ambulance and drove to the hospital with CPR in progress. Critical events were manually timed while the mannequin recorded data on compressions. RESULTS Twenty-three EMS providers participated. Median time to defibrillation was not different for LUCAS compared to manual CPR (p=0.97). LUCAS had a lower median number of compressions per minute (112/min vs. 125/min; IQR = 102-128 and 102-126 respectively; p<0.002), which was more consistent with current American Heart Association CPR guidelines, and percent adequate compression rate (71% vs. 40%; IQR = 21-93 and 12-88 respectively; p<0.002). In addition, LUCAS had a higher percent adequate depth (52% vs. 36%; IQR = 25-64 and 29-39 respectively; p<0.007) and lower percent total hands-off time (15% vs. 20%; IQR = 10-22 and 15-27 respectively; p<0.005). LUCAS performed no differently than manual CPR in median compression release depth, percent fully released compressions, median time hands off, or percent correct hand position. CONCLUSION In our simulation, LUCAS had a higher rate of adequate compressions and decreased total hands-off time as compared to manual CPR. Chest compression quality may be better when using a mechanical device during patient movement in prehospital cardiac arrest patient.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of prehospital insertion of the laryngeal mask airway by primary care paramedics with only classroom mannequin training.

INTRODUCTION The laryngeal mask airway (LMAtrade mark airway) provides adequate ventilation and offers a suitable alternative for airway management in patients with cardiac arrest if primary care paramedics do not have intubation skills or are unable to intubate. Training in the use of the LMA usually occurs in the operating room. OBJECTIVE To describe the use of the LMA by paramedics in preh...

متن کامل

Performance of Prehospital Emergency Medicine Staff in Tracheal Intubation and Related Factors in Mannequin

 Background and purpose: Airway management is a fundamental principle in treatment of emergency patients and reduction of mortality. The purpose of this study was to determine the performance of prehospital emergency medicine servises (EMS) in endotracheal intubation and its related factors in mannequin. Materials and methods: This cross-sectional analytic study was performed in 70 EMS  staff ...

متن کامل

Prehospital randomised assessment of a mechanical compression device in cardiac arrest (PaRAMeDIC) trial protocol

BACKGROUND Survival after out-of-hospital cardiac arrest is closely linked to the quality of CPR, but in real life, resuscitation during prehospital care and ambulance transport is often suboptimal. Mechanical chest compression devices deliver consistent chest compressions, are not prone to fatigue and could potentially overcome some of the limitations of manual chest compression. However, ther...

متن کامل

The PTL, Combitube, laryngeal mask, and oral airway: a randomized prehospital comparative study of ventilatory device effectiveness and cost-effectiveness in 470 cases of cardiorespiratory arrest.

PURPOSE A prehospital study was conducted to assess and compare three alternative airway devices and the oral airway for use by non-Advanced Life Support emergency medical assistants (EMAs). METHOD A modified randomized crossover design was used. The Pharyngeal Tracheal Lumen Airway (PTL), the laryngeal mask (LM), and the esophageal tracheal Combitube (Combi) were compared objectively for suc...

متن کامل

The Effect of Computer Simulation and Mannequin on Nursing Students’ Perception of Self-efficacy in Cardiopulmonary Resuscitation

Introduction: Resuscitation self-efficacy is defined as a judgment of perceived capability to organize and execute the process of care during cardiopulmonary resuscitation. It is believed to be an important factor in teaching vital nursing skills especially cardiopulmonary resuscitation. Therefore, this study aimed to investigate the impact of mannequin-based simulation and computer-based simul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017