Energy Savings Potential of Phase Change Material Integrated Building Envelope in South Texas

نویسندگان

  • Hui Shen
  • Xiaoyu Liu
  • Xiaoyu LIU
چکیده

The performance of phase change material (PCM) integrated building envelope in terms of peak load reduction, peak load time delay and thermal demand improvement was investigated for a prototype detached single family house in a hot climate location. Five market available PCM layers, which can be easily inserted into traditional wall construction, were selected and coupled into different walls and different locations within the wall. Annual simulation results from EnergyPlus indicated the significant effect of PCM integrated envelope for the studied case. The PCM layer of melting temperature of 23 C is determined as the best one for south wall implementation. When it is placed to the interior of the insulation component of the wall, heat flux at heating load peak is reduced by 22.3% and heat flux at cooling load peak is reduced by 12.3%. For ceiling application, the best performing one is the PCM layer of melting temperature of 25 C and when it is placed below the insulation component of the ceiling. Reduction in peak heat flux is 30.2% for heating and 25.8% for cooling. The greater reduction in peak heat flux of ceiling than south wall is due to its larger area. For peak heat flux time delay, all PCM cases show similar effect of about 30 minutes for typical heating time and 60 minutes for typical cooling time. The performance of PCM layers in reducing annual thermal demand is not as evident as in heat flux: reduction in heating demand ranges from 7.9% to 54.34% and reduction in cooling demand ranges from 1.2% to 7.2%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

IRANIAN VERNACULAR ARCHITECTURE: NOTABLE EXAMPLE OF A THERMAL MASS

In some climates, massive buildings made of stone, masonry, concrete, earth and … can be utilized as one of the simplest and most effective ways of reducing building heating and cooling loads. Very often such savings could be achieved in the design stage of the building and with a relatively low-cost. Such declines in building envelope heat losses combined with optimized material configurati...

متن کامل

Annual energy analysis of concrete containing phase change materials for building envelopes

This paper examines the annual energy and cost savings potential of adding microencapsulated phase change material to the exterior concrete walls of an average-sized single family home in California climate zones 3 (San Francisco, CA) and 9 (Los Angeles, CA). The annual energy and cost savings were larger for Southand West-facing walls than for other walls. They were also the largest when the p...

متن کامل

Application of Phase Change Material (PCM) for Cooling Load Reduction in Lightweight and Heavyweight Buildings: Case Study of a High Cooling Load Region of Iran

The application of phase change material (PCM) for energy conservation purposes in the residential buildings was investigated in the present study. Two types of building in terms of materials as the lightweight building (LWB) and heavyweight building (HWB) located in a high cooling load demanding region of Iran were considered for the study. Different types of PCM from organic and inorganic cat...

متن کامل

Investigating the role of high-rise building shell elements in reducing energy consumption (case example: Isfahan Cascade doctors' residential towers)

Significant energy is used to provide and maintain environmental conditions for thermal comfort in high-rise residential buildings, which largely depends on the components of the shell design. Therefore, to achieve high amounts of energy savings in buildings, high-impact design measures must first be defined and then optimized. This study seeks to answer the question of how the components of th...

متن کامل

Utilization of Thermal Mass in the Toronto Net Zero Energy House for Thermal Comfort and Energy Savings

A detailed model of the Net Zero Energy Town House in Toronto is developed in TRNSYS. The incorporation of thermal mass into the building envelope has been demonstrated to contribute to the enhancement of occupant comfort through the reduction of indoor temperature fluctuations. It has also been shown to cause a decrease in the overall energy consumption associated with the heating and cooling ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016