Comparison of conventional and new-generation nickel-titanium files in regard to their physical properties.
نویسندگان
چکیده
INTRODUCTION This study investigated the surface, fractured structure, and physicochemical properties related to cyclic fatigue in various nickel-titanium (NiTi) files. METHODS Among a total of 10 groups of NiTi files, conventional NiTi files (ProFile [Dentsply Maillefer, Ballaigues, Switzerland] and K3 [SybronEndo, Orange, CA]) and new-generation NiTi files (ProFile Vortex [PV; Tulsa Dental Specialties, Tulsa, OK], Vortex Blue [VB; Tulsa Dental Specialties], and K3 XF [XF; SybronEndo, Orange, CA]) with the same tip diameter (ISO size 25) and 2 types of taper (0.04 and 0.06) were used in this study. Scanning electron microscopy of the file surface structure, differential scanning calorimetry, and cyclic fatigue resistance tests were conducted. RESULTS Many mechanical grooves were recognized on the file surface. The surface in the ProFile group was extremely smooth compared with that observed for the other files. Many shallow hollows besides mechanical grooves were noted on the surface in the XF group. A smooth curve was observed in the ProFile, K3, and PV groups. Defined peaks in differential scanning calorimetry were observed in the VB and XF groups. The 0.04 taper files exhibited a statistically higher number of cycles to fracture than the 0.06 taper files in all groups (P < .05). Cracks along the mechanical grooves were observed in the NiTi files, with the exception of the XF group. The start of cracking was detected at U-shape sites in the ProFile group, the cutting edge in the PV and VB groups, and radial islands in the K3 and XF groups. CONCLUSIONS The present findings suggest that new-generation NiTi files are not necessarily improved compared with conventional files.
منابع مشابه
Bending properties of a new nickel-titanium alloy with a lower percent by weight of nickel.
INTRODUCTION The aim of the present study was to evaluate the bending properties of Hyflex instruments, which exhibit a lower percent in weight of nickel (52 Ni %wt) and compare them with other commercially available nickel-titanium (NiTi) rotary instruments. METHODS Ten instruments with tip size 25, 0.06 taper of each of the following NiTi rotary instrumentation techniques were selected for ...
متن کاملA Comparison of Torsional Stress Properties of Three Different Nickel-Titanium Files with Similar Cross-Sectional Design
A COMPARISON OF TORSIONAL STRESS PROPERTIES OF THREE DIFFERENT NICKEL-TITANIUM FILES WITH SIMILAR CROSS-SECTIONAL DESIGN Reid C. Wycoff D.D.S. Marquette University, 2012 The purpose of this study was to compare the in vitro torsional stress characteristics of Twisted Files (SybronEndo, Orange, CA) with two milled files of similar cross section, EndoSequence (Brasseler USA, Savannah, GA) and Pro...
متن کاملCyclic fatigue and torsional resistance of two new nickel - titanium instruments used in reciprocation motion : Reciproc Versus
The use of reciprocating movement (RM) was claimed to increase the resistance of nickel-titanium (NiTi) file to fatigue in comparison to continuous rotation (CR). Recently two new brands of NiTi file have been marketed for use in a RM mode. The purpose of this study was to compare the cyclic fatigue resistance and torsional resistance of these two files; Reciproc and WaveOne. Cyclic fatigue tes...
متن کاملDestruction of Amylopectin in the Presence and Absence of TiO2 Nanoparticles
Today, the use of natural polymers and their replacement with synthetic polymers in various fields of science has attracted much attention. Reducing the associated risks, easy access, and being cost-effective are among the advantages of using natural polymers compared to the synthetic polymers. In this research, the destruction of amylopectin in the presence and absence of titanium dioxide nano...
متن کاملComparison of Hero 642 and K3 rotary nickel-titanium files in curved canals of molars and a systematic review of the literature
The aim of the present study was to compare the root canal preparation ability of rotary nickel-titanium (NiTi) Hero 642 and K3 files in curved mandibular or maxillary molars. A total of 40 extracted mandibular molars with two separate mesial canals, an apical width of approximately size ≤15 and a root canal curvature of 15-30° were randomly divided into two groups and instrumented using Hero 6...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of endodontics
دوره 40 11 شماره
صفحات -
تاریخ انتشار 2014