Successful use of a right ventricular assist device.

نویسندگان

  • P Belcher
  • B Glenville
  • L Cooper
چکیده

Right ventricular failure caused by myocardial infarction may be refractory to treatment designed to support the systemic ventricle. A new type of right ventricular assist device driven by an impeller pump was successfully used for 79 hours after emergency revascularisation after right coronary occlusion. Despite renal failure requiring haemofiltration the patient has now fully recovered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)

Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...

متن کامل

Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs

LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Pimobendan in Chronic Right Heart Failure in a Left Ventricular Assist Device Patient

We report the case of a 76-year-old patient who developed chronic right heart failure 1 year after left ventricular assist device implantation due to ischemic cardiomyopathy. Initial recompensation was achieved through dobutamin, sildenafil, and levosimendan treatment. Yet, discharge was successful only after the off-label use of the oral calcium sensitizer pimobendan. Ten months after discharg...

متن کامل

Successful use of the HeartWare HVAD rotary blood pump for biventricular support.

Left ventricular assist devices (LVADs) using rotary blood pump technology led to significant improvement of results in left ventricular failure. However, patients with concomitant right ventricular failure have not benefited from this new technology so far. We report on the first successful use of 2 HeartWare HVAD centrifugal pumps (HeartWare International, Inc, Framingham, Mass) in biventricu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 58 2  شماره 

صفحات  -

تاریخ انتشار 1987