Occlusion of arterial flow in the extremities at subsystolic pressures through the use of wide tourniquet cuffs.
نویسندگان
چکیده
Tourniquet-induced peripheral neuropathy is at least partially attributable to excessive forces applied to the nerves beneath cuffs inflated to high pressures. Lowering the inflation pressure to the minimum necessary to obtain an effective arrest of blood flow distal to the tourniquet cuff should increase the safety of these systems. Tourniquet cuffs with widths varying from 4.5 cm to 80 cm were applied to the upper and lower extremities of 34 healthy, normotensive volunteers. Occlusion pressure for the arterial system under study was estimated by determining that level of cuff inflation at which the distal pulse became detectable by ultrasonic flowmetry. The occlusion pressure was inversely proportional to the ratio of tourniquet cuff width to limb circumference and was in the subsystolic range at a cuff width to limb circumference ratio above 0.5. Wide tourniquet cuffs can achieve an effective arrest of the regional arterial circulation at subsystolic pressures of inflation. Wide cuffs may reduce the risk of tourniquet-induced injury to underlying soft tissues by lowering the inflation pressure required to secure a bloodless field.
منابع مشابه
The use of lower tourniquet inflation pressures in extremity surgery facilitated by curved and wide tourniquets and an integrated cuff inflation system.
Use of the lowest possible cuff inflation pressure should minimize the pathogenic effects of compression beneath the pneumatic tourniquet. Curved tourniquets (designed to fit conically shaped limbs) and wider tourniquets were associated with significantly lower arterial occlusion pressure (AOP) than standard, straight tourniquets on the arms and legs of 26 normal volunteers. These tourniquets w...
متن کاملTourniquet pain in a volunteer study: effect of changes in cuff width and pressure.
This study examines the relationship between pneumatic tourniquet cuff size, occlusion pressure and the resulting pain. Two tourniquet cuff widths were used, a wide (14 cm) and a narrow cuff (7 cm). Twenty volunteers were divided into two groups for tourniquet application: a pressure group in which the tourniquet was inflated to a pressure equal to the systolic pressure + 100 mmHg, and a satura...
متن کاملWide tourniquet cuffs more effective at lower inflation pressures.
Longitudinal and radial tissue-fluid pressure distributions were determined beneath and adjacent to wide (12 and 18 cm) pneumatic tourniquet cuffs placed on intact human cadaveric arms and legs, respectively. Tissue fluid pressures exhibited relatively broad maxima at midcuff, and in most cases showed no differences at the various depths studied. Limb circumference was not a determining factor ...
متن کاملSurvey of tourniquet use in orthopaedic foot and ankle surgery.
BACKGROUND Tourniquet technique varies among foot and ankle surgeons, and to establish a standard practice guideline the current standard of care should be examined. METHODS One hundred and forty responses were received after 253 surveys were mailed to American Orthopaedic Foot and Ankle Society (AOFAS) members, concerning type of tourniquets, location, and pressures used. RESULTS Cuff pres...
متن کاملTourniquet safety in lower leg applications.
PURPOSE To reduce the chance of injury due to pneumatic tourniquet use, the minimum cuff pressure required to maintain a bloodless field should be used. The purpose of this study was to find out if Limb Occlusion Pressure (LOP--the cuff pressure required to occlude arterial flow) is lower with a wide contoured cuff than with a standard width cylindrical cuff at the calf, if cuff pressures based...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 286 شماره
صفحات -
تاریخ انتشار 1993