Overlapping thin-section fast spin-echo MR of the large vestibular aqueduct syndrome.
نویسندگان
چکیده
PURPOSE To evaluate a high-resolution, thin-section fast spin-echo MR imaging technique of the inner ear to identify the large vestibular aqueduct syndrome seen on temporal bone CT scans. METHODS We retrospectively reviewed the temporal bone CT scans of 21 patients with hearing loss and enlarged bony vestibular aqueducts by CT criteria. High-resolution fast spin-echo MR imaging was then performed on these patients using dual 3-inch phased-array receiver coils fixed in a temporomandibular joint holder and centered over the temporal bones. MR imaging included axial and oblique sagittal fast spin-echo sequences. The diameter of the midvestibular aqueduct on CT scans and the signal at the level of the midaqueduct on MR images were measured on axial sequences, then compared. High-resolution MR imaging with the same protocol was performed in 44 control subjects with normal ears, and similar measurements were taken. RESULTS The average size of the enlarged bony vestibular aqueduct on CT scans was 3.7 mm, and the average width of the signal from within the enlarged aqueduct on MR images was 3.8 mm. Statistical analysis showed excellent correlation. MR images alone displayed the enlarged extraosseous endolymphatic sac, which accompanies the enlarged aqueduct in this syndrome. Five ears in three patients with enlarged bony vestibular aqueducts on CT scans showed no evidence of an enlarged endolymphatic duct or sac on MR images. An enlarged endolymphatic sac was seen on MR images in one patient with a bony vestibular aqueduct, which had normal measurements on CT scans. MR imaging alone identified a single case of mild cochlear dysplasia (Mondini malformation). In the 88 normal ears studied, the average size of the endolymphatic sac at its midpoint between the common crus and the external aperture measured on MR images was 0.8 mm (range, 0.5 to 1.4 mm). In 25% of the normal ears, no signal was seen from within the vestibular aqueduct. CONCLUSION Thin-section, high-resolution fast spin-echo MR imaging of the inner ear is complementary to CT in studying patients with the large vestibular aqueduct syndrome, as MR imaging better displays the soft tissue and fluid of the membranous labyrinth.
منابع مشابه
Lymphoma: Master of Chicanery
1. Dahlen RT, Harnsberger HR, Gray SD, et al. Overlapping thinsection fast spin-echo MR of the large vestibular aqueduct syndrome. AJNR Am J Neuroradiol 1997;18:67–75 2. Schmalbrock P, Dailiana T, Chakeres DW, et al. Submillimeterresolution MR of the endolymphatic sac in healthy subjects and patients with Meniere disease. AJNR Am J Neuroradiol 1996;17: 1707–1716 3. Salt AN, Henson MM, Gewalt SL...
متن کاملFast multiphase MR imaging of aqueductal CSF flow: 1. Study of healthy subjects.
Gradient-echo MR sequences are more sensitive to flow phenomena than spin-echo sequences are. We investigated aqueductal CSF flow by fast multiphase imaging. Fast multiphase imaging offers the opportunity to perform a dynamic study of fluid motion that is synchronous with the cardiac cycle. A section perpendicular to the cerebral aqueduct was imaged in 18 healthy volunteers. Serial, gated (ever...
متن کاملLarge vestibular aqueduct syndrome with high CT density and high MR signal intensity.
We report a case of large vestibular aqueduct syndrome with a markedly dilated endolymphatic sac bilaterally. The density and signal intensity of the extraosseous portion of the sac were higher than those of cerebrospinal fluid on CT and MR studies. The findings may represent protein-rich and hyperosmolar fluid within the endolymphatic sac.
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملHigh-resolution MR cisternography of the cerebellopontine angle, obtained with a three-dimensional fast asymmetric spin-echo sequence in a 0.35-T open MR imaging unit.
High-resolution MR cisternography performed with 3D fast asymmetric spin-echo imaging (3D fast spin-echo with an ultra-long echo train length and asymmetric Fourier imaging) was optimized in a 0.35-T open MR imaging unit. The 0.35- and 1.5-T images of the two volunteers and three patients with acoustic schwannomas were then compared. The optimal parameters for images obtained by 3D fast asymmet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 18 1 شماره
صفحات -
تاریخ انتشار 1997