Determination of hemolysis thresholds by the use of data loggers in pneumatic tube systems.
نویسندگان
چکیده
BACKGROUND Pneumatic tube systems (PTSs) for the transport of blood samples are regaining popularity in medical centers after earlier reports that their use could introduce preanalytical distortions such as hemolysis and changes in blood gases. METHODS We drew duplicate blood samples from 30 volunteers. One sample was hand transported, and the other sample was transported through a PTS together with a mini-data logger that provided continuous measurements of temperature, humidity, pressure, and acceleration. After transport the samples were analyzed at the same time. We looked for possible relationships of the transport method and the parameters measured by the data loggers with differences in hematological parameters, standard clinical chemistry analyses, blood coagulation, erythrocyte sedimentation rate, and blood gas analysis. RESULTS There were no significant differences in temperature, humidity, and pressure between the methods of transport, but we observed significant differences in 3-axis accelerations. The combined effect of these forces could be described by the right-tailed area under the vector sum acceleration distribution. Our data show that this area correlated with PTS speed and that PTS speed and the area under the curve exhibited a direct relation to the degree of hemolysis. CONCLUSIONS Assessment of 3-axis acceleration by use of data loggers can be used to identify preanalytical deviations that result from the transportation of blood samples in PTSs. Our approach could be used for the evaluation and regular control of PTSs without the need for repeated blood drawing and laboratory analyses.
منابع مشابه
Hemolysis associated with pneumatic tube system transport for blood samples
OBJECTIVE The frequency of hemolysis of blood samples may be increased by transport in a pneumatic tube system. The purpose of this study was to evaluate the effect of pneumatic tube system transport on hemolysis of blood samples. METHODS Blood samples were transported from the emergency department to the hospital laboratory manually by hospital staff (49 patients) or with a pneumatic tube sy...
متن کاملDoes Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
INTRODUCTION Our goal was to determine if the hemolysis among blood samples obtained in an emergency department and then sent to the laboratory in a pneumatic tube system was different from those in samples that were hand-carried. METHODS The hemolysis index is measured on all samples submitted for potassium analysis. We queried our hospital laboratory database system (SunQuest(®)) for potass...
متن کاملPosition Control of a Pulse Width Modulated Pneumatic Systems: an Experimental Comparison
In this study, a new adaptive controller is proposed for position control of pneumatic systems. Difficulties associated with the mathematical model of the system in addition to the instability caused by Pulse Width Modulation (PWM) in the learning-based controllers using gradient descent, motivate the development of a new approach for PWM pneumatics. In this study, two modified Feedback Error L...
متن کاملDetermination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays
Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...
متن کاملEffect of Pneumatic Tube System Transport on Serum and Plasma Enzyme Levels
Pneumatic tube systems of various lengths are routinely used in many hospitals to transport blood collection tubes (serum, plasma, whole blood) to the testing laboratory. The present study evaluated the changes in the levels of enzymes in two different tube system transports within the hospital system. Two tubes of blood, one SST (Serum) tube and one Lithium Heparin (Plasma) tube, were collecte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 57 10 شماره
صفحات -
تاریخ انتشار 2011