Voltammetric determination of isoxsuprine and fenoterol in dosage forms and biological fluids through nitrosation.

نویسندگان

  • F Belal
  • H A Al-Malaq
  • A A Al-Majed
چکیده

A simple and highly sensitive voltammetric method was developed for the determination of isoxsuprine HCl (I) and fenoterol HBr (II) in dosage forms and biological fluids. The method is based on treatment of the two compounds with nitrous acid followed by measuring the cathodic current produced by the resulting nitroso derivatives. The voltammetric behavior was studied adopting Direct Current (DCt), Differential Pulse (DPP) and Alternating Current (ACt) polarography. Both compounds produced well-defined, diffusion-controlled cathodic waves over the whole pH range in Britton-Robinson buffers (BRb). At pH 11 and pH 9, the values of diffusion-current constants (Id), were 9.4 +/- 0.3 and 7.7 +/- 0.4 for I and II, respectively. The current-concentration plots for I were rectilinear over the range of 0.6-12 microg/ml and 0.1-12 microg/ml in the DCt and DPP modes, respectively. As for II, the range was 1-20 microg/ml and 0.1-20 microg/ml in the DCt and DPP modes, respectively. The minimum detectability (S/N = 2) were 0.02 microg/ml (approximately 6 x 10(-8) M) and 0.01 microg/ml (approximately 2.6 x 10(-8) M) for I and II, respectively, adopting the DPP mode. The proposed method was applied to the determination of both compounds in dosage forms and the results obtained were in good agreement with those obtained using reference methods. The proposed method was further applied to the determination of isoxsuprine in spiked human urine and plasma. The percentage recoveries adopting the DPP mode were 98.84 +/- 1.18 and 99.26 +/- 0.97, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorimetric determination of isoxsuprine hydrochloride in pharmaceuticals and biological fluids.

Two simple and highly sensitive fluorimetric methods have been developed for the determination of isoxsuprine hydrochloride in bulk, in dosage forms and in biological fluids. The first method involves the direct measurement of the native fluorescence of the drug in the concentration range 0.4-4.0 microg ml(-1), the second method is based on the oxidation of isoxsuprine HCl with cerium(IV) follo...

متن کامل

Voltammetric determination of benazepril and ramipril in dosage forms and biological fluids through nitrosation.

A simple and highly sensitive voltammetric method was developed for the determination of benazepril (I) and ramipril (II). The compounds were treated with nitrous acid, and the cathodic current produced by the resulting nitroso derivatives was measured. The voltammetric behavior was studied by adopting direct current (DCt), differential pulse (DPP), and alternating current (ACt) polarography. B...

متن کامل

Determination of phenolic sympathomimetic drugs in pharmaceutical samples and biological fluids by flow-injection chemiluminescence.

A rapid and highly sensitive flow-injection chemiluminometric method was developed for determination of 3 sympathomimetic drugs, namely, etilefrine hydrochloride, isoxsuprine hydrochloride, and prenalterol hydrochloride. The method is based on chemiluminescence induced by oxidation of drugs with acidified potassium permanganate in the presence of formic acid as a carrier. The calibration graphs...

متن کامل

Kinetic Spectrophotometric Determination of Isoxsuprine in Dosage Forms Through Derivatisation with 4-Chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl)

A simple and sensitive kinetic spectrophotometric method was developed for the determination of isoxsuprine in pharmaceutical preparations. The method is based upon a kinetic investigation of the coupling reaction between isoxsuprine HCl and 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) in borate buffer of pH 7.8 for a fixed time of 30 min. The absorbance of the yellow coloured product was m...

متن کامل

A Review of Current Trends and Advance in Analytical Methods for Determination of Simvastatin Electrochemical by different electrodes

Simvastatin is a hypolipidemic drug used with exercise, diet and weight – loss to control elevated cholesterol or hypercholesterolemia. It is a member of the Statin class of pharmaceuticals. This paper delives voltammetric techniques is an electrochemical technique used in analytical applications and fundamental studies of electrode mechanism. This review summarizes some of the recent developme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2000