Recommendation for measuring and reporting chloride by ISEs in undiluted serum, plasma or blood.
نویسندگان
چکیده
The proposed recommendation for measuring and reporting chloride in undiluted plasma or blood by ion-selective electrodes (ISEs) will provide results that are identical to chloride concentrations measured by coulometry for standardized normal plasma or blood samples. It is applicable to all current ISEs dedicated to chloride measurement in undiluted samples that meet the requirements. However, in samples with reduced water concentration, results by coulometry are lower than by ion-selective electrode due to volume displacement. The quantity measured by this standardized ISE procedure is called the ionized chloride concentration. It may be clinically more relevant than the chloride concentration as determined by coulometry, photometry or by ISE after dilution of the sample.
منابع مشابه
Calculation of plasma chloride levels using blood gas measurements
Objective: Chloride is the major plasma anion. There are several methods available for the determination of serum chloride levels. Unfortunately these methods are sometimes not available in the urgent setting where values are needed. Here we describe...
متن کاملRate of Glucose Utilization by Blood Cells in Serum and Plasma Specimens With or Without Using Preservative
Objective: This study aims to estimate and compare the time-course change in blood glucose levels by blood cells in serum, and plasma with or without preservatives, which may reflect the rate of glucose utilization by blood cells. Method: This laboratory-based cross-sectional study was carried out using a blood specimen of 28 participants among which 14 were diagnosed with diabetes and 14 were...
متن کاملLactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.
We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow Springs Instrument Co. (YSI), Yellow Springs, OH] and another for measuring la...
متن کاملNeutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum.
The concentration of free, ionized magnesium in undiluted blood serum can be determined potentiometrically with a new magnesium-selective carrier in polymeric membrane electrodes (by weight 66% plasticizer, approximately 33% polyvinyl chloride and approximately 1% ionophore). However, discrimination of calcium by the new ionophore-added membrane is not sufficient to keep calcium interference to...
متن کاملEvaluation of Brain Natriuretic Peptide, Tumor Necrosis Factor and Interleukin-6 Plasma Levels in Infants and Children with Congenital Heart Disease
Background Congenital heart disease (CHD) is the most common cause of major congenital birth defect. The aim of this study was to investigate the association of CHD with serum levels of Tumor necrosis factor-α (TNFα), Interleukin 6 (IL-6), and B-type Natriuretic Peptide (BNP) in infant and children. Materials and Methods The present study was conducted in Heshmat heart hospital and 17 Shahrivar...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 44 3 شماره
صفحات -
تاریخ انتشار 2006