The BioPlex 2200 automated analyzer (Bio-Rad Laboratories, Hercules, CA) is a recently developed multiplex analyzer that enables the detection of anti-Toxoplasma, -rubella, and -cytomegalovirus antibodies in the same assay. The aim of this study was to compare this new technology (using the BioPlex 2200 ToRC IgG/IgM kit) in critical cases of serodiagnosis of toxoplasmosis (acute, chronic, or congenital infections and cases with discrepant results) to the technologies used in our routine practice, i.e., the Platelia IgG/IgM enzyme-linked immunosorbent assays (ELISAs) (Bio-Rad Laboratories) and the Toxo-Screen direct agglutination assay (bioMérieux, Lyon, France). Overall, most cases of false-positive/negative results obtained with the Platelia IgG or Toxo-Screen assay were corrected by the BioPlex 2200 ToRC IgG (87.5%). Furthermore, the analysis of 35 sequences of sera showed a trend toward a more rapid decrease of IgM titers by BioPlex 2200 than by Platelia. These results for IgM detection can be explained by a weaker detection of residual IgM. Indeed, among 23 serum samples from patients with probable past infection with long-lasting IgM (Platelia M positive and IgG avidity index, ≥0.5), the BioPlex 2200 Toxoplasma IgM assay was positive for only 11 serum samples. In our panel of critical cases comprising 156 serum and 6 cord blood samples from 103 patients with acute, chronic, or congenital infection, the BioPlex 2200 IgG assay was a sensitive (97.8%) and specific (91.3%) method for IgG detection. The high specificity (97.4%) of IgM detection combined with the shorter kinetics of IgM titers may considerably reduce the number of residual IgM detections, thus yielding more precise diagnoses of acute infections.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Bio-Rad BioPlex 2200 syphilis multiplex flow immunoassay for the detection of IgM- and IgG-class antitreponemal antibodies.

The laboratory diagnosis of syphilis is based primarily upon serologic findings. Historically, serologic testing for syphilis has relied on assays such as rapid plasma reagin, fluorescent treponemal antibody absorption, Treponema pallidum particle agglutination (TP-PA), and more recently, enzyme immunoassay (EIA). In this study, we evaluated the performance of a novel multiplex flow immunoassay...

متن کامل

Detection of immunoglobulin M antibodies specific for Toxoplasma gondii with increased selectivity for recently acquired infections.

Toxoplasma gondii infections can cause serious complications in pregnant women, leading to miscarriage, stillbirth, and birth defects. Definitive diagnosis of T. gondii acute infection is therefore critical for the clinical management of a mother and her fetus. Positive immunoglobulin M (IgM) results are not sufficient as evidence of recent infection, as these antibodies are often present for m...

متن کامل

Clinical evaluation of BioPlex 2200 HIV Ag-Ab, an automated screening method providing discrete detection of HIV-1 p24 antigen, HIV-1 antibody, and HIV-2 antibody.

Early and accurate diagnosis is essential for optimal therapeutic outcomes in patients infected with HIV. Currently, none of the commercially available fourth-generation assays differentiate HIV-1 and HIV-2 antibodies (Ab) or the HIV-1 p24 antigen (Ag). The aim of this study was to evaluate the performance of a novel assay, the BioPlex 2200 HIV Ag-Ab. This assay uses a multiplex flow immunoassa...

متن کامل

Highlights on Novel Technologies for the Detection of Antibodies to Ro60, Ro52, and SS-B

OBJECTIVE We aimed to compare a chemiluminescent immunoassay (CIA, QUANTA Flash) on BIO-FLASH with a multiplex flow immunoassay (MFI) on BioPlex 2200 for the detection of antibodies to Ro60, Ro52, and SS-B. METHODS The study included 241 samples, from patients suffering from systemic autoimmune diseases (n = 108) as well as disease controls (n = 133). All samples were tested for anti-Ro52, an...

متن کامل

DEMONSTRATION OF LOCAL ANTITOXOPLASMIC IMMUNOGLOBULIN G PRODUCTION IN OCULAR TOXOPLASMOSIS, TRACED BY ENZYME IMMUNOASSAY OF AQUEOUS HUMOR AND SERUM

Forty patients with cataracts, as well as 40 patients with proven ocular toxoplasmosis were enrolled in this prospective clinical study. Serum IgG and aqueous IgG in both groups were measured by enzyme-linked immunosorbent assay (ELISA) and the corresponding ratios were calculated. Serum IgG/aqueous humor IgG ratio was less than 100 in the patient group and more than 100 in the control gro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and vaccine immunology : CVI

دوره 21 4  شماره 

صفحات  -

تاریخ انتشار 2014