Simplified Method for Insertion of Steerable Guide into the Left Atrium Using a Pigtail Guide Wire During the MitraClip(®) Procedure: A Technical Tip.
نویسندگان
چکیده
BACKGROUND To assess whether a new floppy pigtail guidewire provides sufficient support for introduction of the 22F-steerable guide catheter (SG) into the left atrium and is less time-consuming during the MitraClip(®) -procedure without necessity of probing and inserting a stiff wire into the pulmonary vein. METHODS In group 1, traditional probing of the left upper pulmonary vein and insertion of a standard stiff wire was used. In group 2, direct insertion of the floppy pigtail guidewire directly after transseptal puncture was used. RESULTS Patients in group 1 (n = 18) and group 2 (n = 21) did not differ significantly with respect to mitral regurgitation severity (3.2 ± 0.4 vs 3.2 ± 0.4; P = 0.814) and etiology (functional 78% vs 71%, P = 0.651). Comparing both methods, a significant reduction in time-to-SG was observed in group 2 versus group 1 (17 ± 7 minutes vs 30 ± 11 minutes; P = 0.001). The rate of crossing failures was 0% with use of the floppy pigtail guidewire as well as with the traditional technique. No complications were observed with use of the floppy pigtail guidewire. CONCLUSIONS Utilization of a thin, floppy pigtail guidewire for left atrium access is safe and markedly accelerates insertion of the SG for the MitraClip(®) -procedure without crossing failures of the atrial septum.
منابع مشابه
Evaluation of Nasogastric Tube Insertion with or without Guide Wire during Laparoscopic Cholecystectomy in Imam Reza AJA Hospital
Purpose: According to frequent needs to gastric decompression by nasogastric tube insertion during laparoscopic Cholecystectomy, the current comparative study was accomplished through single blind clinical trial considering both the presence and the absence of guide wire insertion. Materials and Methods: Twenty patients were selected for elective surgery of laparoscopic Cholecystectomywith ...
متن کاملحل مشکل جاگذاری کاتتر ورید مرکزی با استفاده از کاتتر وریدی: مقاله تکنیکال
Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will ...
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...
متن کاملSteerable antegrade stenting: a new trick of the trade.
INTRODUCTION Whereas a retrograde attempt to insert an indwelling stent is performed in lithotomy position, usually renal access is gained in a prone position. To overcome the time loss of patient repositioning, a renal puncture can be performed in a modified lithotomy position with torqued truncus and slightly elevated flank. There is a two-fold advantage of this position: transurethral and tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of interventional cardiology
دوره 28 5 شماره
صفحات -
تاریخ انتشار 2015