CT sinogram-consistency learning for metal-induced beam hardening correction

نویسندگان

  • Hyung Suk Park
  • Sung Min Lee
  • Hwa Pyung Kim
  • Jin Keun Seo
چکیده

Purpose: This paper proposes a sinogram-consistency learning method to deal with beamhardening related artifacts in polychromatic computerized tomography (CT). The presence of highly attenuating materials in the scan field causes an inconsistent sinogram, that does not match the range space of the Radon transform. When the mismatched data are entered into the range space during CT reconstruction, streaking and shading artifacts are generated owing to the inherent nature of the inverse Radon transform Methods: The proposed learning method aims to repair inconsistent sinogram by removing the primary metal-induced beam-hardening factors along the metal trace in the sinogram. Taking account of the fundamental difficulty in obtaining sufficient training data in a medical environment, the learning method is designed to use simulated training data and a patient-type specific learning model is used to simplify the learning process. Results: The feasibility of the proposed method is investigated using a dataset, consisting of real CT scan of pelvises containing simulated hip prostheses. The anatomical areas in training and test data are different, in order to demonstrate that the proposed method extracts the beam hardening features, selectively. The results show that our method successfully corrects sinogram inconsistency by extracting beam-hardening sources by means of deep learning. Conclusion: This paper proposed a deep learning method of sinogram correction for beam hardening reduction in CT for the first time. Conventional methods for beam hardening reduction are based on regularizations, and have the fundamental drawback of being not easily able to use manifold CT images, while a deep learning approach has the potential to do so.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iterative correction of beam hardening artifacts in CT.

PURPOSE To reduce beam hardening artifacts in CT in case of an unknown x-ray spectrum and unknown material properties. METHODS The authors assume that the object can be segmented into a few materials with different attenuation coefficients, and parameterize the spectrum using a small number of energy bins. The corresponding unknown spectrum parameters and material attenuation values are estim...

متن کامل

Metal Artifact Reduction in CT via Ray Profile Correction

In computed tomography (CT), metal implants increase the inconsistencies between the measured data and the linear assumption made by the analytical CT reconstruction algorithm. The inconsistencies appear in the form of dark and bright bands and streaks in the reconstructed image, collectively called metal artifacts. The standard method for metal artifact reduction (MAR) replaces the inconsisten...

متن کامل

Computed tomographic beam-hardening artefacts: mathematical characterization and analysis.

This paper presents a mathematical characterization and analysis of beam-hardening artefacts in X-ray computed tomography (CT). In the field of dental and medical radiography, metal artefact reduction in CT is becoming increasingly important as artificial prostheses and metallic implants become more widespread in ageing populations. Metal artefacts are mainly caused by the beam-hardening of pol...

متن کامل

Automatic Beam Hardening Correction For CT Reconstruction

In computed tomography (CT) the quality of reconstructed images depends on several reasons: the quality of the set-up calibration; precision of the mathematical model, used in the reconstruction procedure; the reconstruction technique used; quality of the numerical implementation of the reconstruction algorithm. Most of fast reconstruction algorithms use the X-ray monochromaticity assumption. I...

متن کامل

The application of X-ray beam hardening correction based on polynomial fitting in local scan

2 national X ray digital imaging center; Mianyang,China Abstract Beam Hardening effect would be induced due to broad energy spectrum of X-ray. Beam Hardening would lead to artifacts in CT reconstructed images, such as cupping artifact, streak artifact and metal artifact, so that the quality of CT image degrades. One efficient beam hardening correction method is building a mathematical law betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017