Variation of pH-measurement in platelet concentrates.
نویسندگان
چکیده
To measure pH in platelet concentrates, blood gas analysers with different calibration principles may be used. In this study, variances observed in pH measurements with two types of blood gas analysers were investigated. pH was measured in crystalloid solutions (platelet additive solution (PAS-II), phosphate-buffered solutions) and two types of platelet concentrates (containing 100% plasma, or 65% PAS-II/35% plasma) with two blood gas analysers: either using liquid and gas calibration (AVL 945), or only liquid calibration (AVL OMNI). These measurements were compared with a reference method. Especially for PAS-II, large variation in pH was observed between AVL 945, AVL OMNI and the reference method: 6.91 +/- 0.02, 7.35 +/- 0.02 and 7.188 +/- 0.010, respectively (mean +/- SD; n = 12, P < 0.0001, paired t-test). A significant difference in pH was also found for platelet concentrates in 65% PAS/35% plasma (6.88 +/- 0.09 on AVL 945 and 7.02 +/- 0.09 on AVL OMNI, n = 134, P < 0.0001). Comparison with the reference method revealed minor differences with AVL 945, whereas AVL OMNI gave a mean difference in pH of + 0.17. Platelets in 100% plasma revealed smaller differences (6.93 +/- 0.13 for AVL 945 and 6.99 +/- 0.13 for AVL OMNI, n = 95, P < 0.0001). We conclude that different blood gas analysers can yield different pH values, especially in weak buffered solutions such as platelet concentrates in PAS-II. Validation of blood gas analysers for pH measurement of these solutions is therefore mandatory.
منابع مشابه
Evaluation of microRNAs; mir223, mir222 and mir92a levels in the Platelet-derived microparticles in the Platelet concentrates produced by Platelet Rich Plasma method during storage
Abstract Background and Objectives Platelets release microparticles containing cellular components, including microRNAs, during storage. Assessment of these microRNAs is one of the markers for evaluation of platelet storage lesions. The aim of the present study was to evaluate the level of changes in the expression of mir-223, mir-92a and mir-222 during storage in platelets prepared by platele...
متن کاملComparison of Diagnostic Procedures for Platelet Products Contaminated with Strains of Staphylococcus Epidermidis and Klebsiella
Abstract Background and Objective: Given that microbial contamination is the third largest cause of mortality caused blood transfusion, the examination of contamination in platelet concentrates is essential in blood transfusion centers. The purpose of this study was to achieve a rapid test for bacterial contamination of platelets concentration. Material and Methods: This laboratory ...
متن کاملتاثیر فیلتراسیون پیش از ذخیره کردن بر فعال شدن پلاکتها در فراوردههای پلاکتی
Preparation conditions and platelet storage for transfusion may cause platelet activation, which contributes to decreased ability of stored platelet to function and survive in vivo after transfusion compared with that seen with freshly prepared platelets. Using flowcytometry, we investigated platelet membrane expression of CD62P, CD63 in platelet stored for up to 3 days under standard blood ba...
متن کاملFlow Cytometric Measurement of CD41/CD61 and CD42b Platelet Receptors and Clotting Assay of Platelet Factor 3 During Long Term-Storage of Platelet Concentrates
Background: The purpose of the present in vitro study was to evaluate the effect of long term storage of conventional platelet concentrates (PCs) on major platelet receptors CD42b and CD41/CD61 by flow cytometry method and also measuring the overall platelet procoagulant activity status using platelet factor 3 (PF3) assay. Materials and Methods: Six random units of conventional platelet conce...
متن کاملFlow Cytometric Measurement of CD41/CD61, CD42b Platelet Receptors and Platelet Factor 3 Activity in Lyophilized Infusible Platelet Membrane Preparation
Background: The short life time of human platelet units has led to a chronic shortage of fresh platelets in blood transfusion centers. Many approaches have been investigated experimentally to produce new hemostatically active platelet products that are capable of long term storage. Infusible platelet membrane (IPM) prepared from fresh or outdated human platelets have been developed as an altern...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Transfusion medicine
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2001