Influence of heart rate on fractional flow reserve, pressure drop coefficient, and lesion flow coefficient for epicardial coronary stenosis in a porcine model.
نویسندگان
چکیده
A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. We hypothesized that the pressure drop coefficient (CDP(e), ratio of transstenotic pressure drop and distal dynamic pressure), lesion flow coefficient (LFC, square root of ratio of limiting value CDP and CDP at site of stenosis) derived from fluid dynamics principles, and fractional flow reserve (FFR, ratio of average distal and proximal pressures) are independent of HR and can significantly differentiate between the severity of stenosis. Cardiac catheterization was performed on 11 Yorkshire pigs. Simultaneous measurements of distal coronary arterial pressure and flow were performed using a dual sensor-tipped guidewire for HR < 120 and HR > 120 beats/min, in the presence of epicardial coronary lesions of <50% AS and >50% AS. The mean values of FFR, CDP(e), and LFC were significantly different (P < 0.05) for lesions of <50% AS and >50% AS (0.88 ± 0.04, 0.76 ± 0.04; 62 ± 30, 151 ± 35, and 0.10 ± 0.02 and 0.16 ± 0.01, respectively). The mean values of FFR and CDP(e) were not significantly different (P > 0.05) for variable HR conditions of HR < 120 and HR > 120 beats/min (FFR, 0.81 ± 0.04 and 0.82 ± 0.04; and CDP(e), 95 ± 33 and 118 ± 36). The mean values of LFC do somewhat vary with HR (0.14 ± 0.01 and 0.12 ± 0.02). In conclusion, fluctuations in HR have no significant influence on the measured values of CDP(e) and FFR but have a marginal influence on the measured values of LFC. However, all three parameters can significantly differentiate between stenosis severities. These results suggest that the diagnostic parameters can be potentially used in a better assessment of coronary stenosis severity under a clinical setting.
منابع مشابه
Influence of Heart Rate and Contractility on Coronary Diagnostic Parameters with Normal Microvasculature in Porcine Model
1 ABSTRACT Invasive guide-wire measurements are used to assess coronary lesion severity under clinical settings. The objective of the present research is to determine the influence of heart rate (HR) and contractility (CY) on fractional flow reserve (FFR; the ratio of distal pressure to proximal pressure at a stenotic section) and pressure drop coefficient (CDPe; the ratio of trans-stenotic pre...
متن کاملEffect of changes in contractility on pressure drop coefficient and fractional flow reserve in a porcine model.
OBJECTIVES AND BACKGROUND Decisions based on invasive functional diagnostic measurements are often made in the setting of fluctuating hemodynamic variables that may alter resting or hyperemic measurements. The purpose of this investigation is to analyze the effect of myocardial contractility (CY) on invasive functional parameters. We hypothesize that the pressure drop coefficient (CDPe; ratio o...
متن کاملDiagnostic cutoff for pressure drop coefficient in relation to fractional flow reserve and coronary flow reserve: A patient-level analysis.
OBJECTIVES AND BACKGROUND Functional assessment of intermediate coronary stenosis during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular resistance (HMR). CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a nondimension...
متن کاملCharacterizing momentum change and viscous loss of a hemodynamic endpoint in assessment of coronary lesions.
Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance ...
متن کاملDiagnostic performance of pressure drop coefficient in relation to fractional flow reserve and coronary flow reserve.
OBJECTIVES AND BACKGROUND Functional assessment of coronary lesion severity during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR; pressure derived) and coronary flow reserve (CFR; flow derived). However, the complex hemodynamics of stenosis might not be sufficiently explained by either pressure or flow alone, particularly in the case of inter...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 300 1 شماره
صفحات -
تاریخ انتشار 2011