Impact of intraocular lens haptic design and orientation on decentration and tilt.

نویسندگان

  • Alja Crnej
  • Nino Hirnschall
  • Yutaro Nishi
  • Vinod Gangwani
  • Juan Tabernero
  • Pablo Artal
  • Oliver Findl
چکیده

PURPOSE To assess the effect of intraocular lens (IOL) orientation (vertical versus horizontal) and haptic design (1-piece versus 3-piece) on centration and tilt using a Purkinje meter. SETTING Moorfields Eye Hospital NHS Foundation Trust, London, United Kingdom. DESIGN Randomized pilot study with intrapatient comparison. METHODS In part 1 of this study, patients received plate-haptic IOLs (Akreos Adapt) in both eyes that were positioned vertically in 1 eye and horizontally in the other eye. In part 2, patients received a 1-piece IOL (Acrysof SA60AT) in 1 eye and a 3-piece IOL (Acrysof MA60AC) in the contralateral eye. Decentration and tilt were measured 1 month and 3 months postoperatively with a new Purkinje meter. RESULTS In part 1 (n = 15), the mean decentration of plate-haptic IOLs was 0.4 mm ± 0.2 (SD) with vertical orientation and 0.4 ± 0.2 mm with horizontal orientation and the mean tilt, 1.5 ± 1.1 degrees and 2.9 ± 0.9 degrees, respectively. In part 2 (n = 15), the mean decentration was 0.4 ± 0.3 mm with 1-piece IOLs and 0.6 ± 0.8 mm with 3-piece IOLs and the mean tilt, 2.2 ± 7.2 degrees and 5.3 ± 2.4 degrees, respectively. CONCLUSIONS Three-piece IOLs had a greater tendency toward more decentration than 1-piece IOLs, perhaps because of slight deformation of 1 or both haptics during implantation or inaccuracies in production when the haptics are manually placed into the optic. The IOL orientation for plate-haptic IOLs appeared to have no effect on IOL position. The Purkinje meter was useful in assessing the capsule bag performance of the IOLs. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned. Additional disclosures are found in the footnotes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار

Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...

متن کامل

Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design

PURPOSE To compare the anterior capsule contraction and intraocular lens (IOL) decentration among three types of IOL to determine the influence of haptic design on anterior capsule stability. METHODS One hundred fifty patients were enrolled in this prospective, randomized study and 260 eyes underwent implantation of one of the following IOLs: modified L-haptic IOL (n = 74), modified C-haptic ...

متن کامل

Intraocular lens tilt and decentration measurements: Purkinje imaging versus Scheimpflug imaging

Purpose: To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems. Methods: Measurements of IOL tilt and decentration were obtained using a commercial Scheimpflug system (Pentacam, Oculus) and custom algorithms, and a custom-built Purkinje imaging apparatus. Both methods were validated with a physical model eye where tilt and decentration can b...

متن کامل

Research on Calculation of the IOL Tilt and Decentration Based on Surface Fitting

The tilt and decentration of intraocular lens (IOL) result in defocussing, astigmatism, and wavefront aberration after operation. The objective is to give a method to estimate the tilt and decentration of IOL more accurately. Based on AS-OCT images of twelve eyes from eight cases with subluxation lens after operation, we fitted spherical equation to the data obtained from the images of the ante...

متن کامل

Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imaging. Validation study.

PURPOSE To measure tilt and decentration of intraocular lenses (IOLs) with Scheimpflug and Purkinje imaging systems in physical model eyes with known amounts of tilt and decentration and patients. SETTING Instituto de Optica Daza de Valdés, Consejo Superior de Investigaciones Científicas, Madrid, Spain. METHODS Measurements of IOL tilt and decentration were obtained using a commercial Schei...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 37 10  شماره 

صفحات  -

تاریخ انتشار 2011