Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners.
نویسندگان
چکیده
The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg) with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s(-1) with a 0.56 m·s(-1) increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg(-1)·min(-1) and 181 ± 13 beats·min(-1). The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99) with small standard errors of regression (i.e. Sy.x < 5% at the velocity associated with the 2 and 4 mmol·L(-1) lactate thresholds). The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods. Key pointsHeart rate is used in the control of exercise intensity in endurance sports.However, few studies have quantified the precision of its relationship with oxygen uptake in highly trained runners.We evaluated twelve elite half-marathon runners during track running at various intensities and established three regressions: oxygen uptake / heart rate; heart rate / running velocity and oxygen uptake / running velocity.The three regressions presented, respectively, imprecision of 4,2%, 2,75% and 4,5% at the velocity associated with the 4 mmol·L(-1) threshold.The results of the present study show that, in highly trained runners, it is possible to use heart rate as an accurate index of the external work rate during sub maximal running speeds.
منابع مشابه
The oxygen uptake - work-output relationship of runners during graded cycling exercise: sprinters vs. endurance runners.
In order to study oxygen consumption (VO2) for a given work load at the exhaustive level of a graded cycling exercise in well-trained runners, a progressive cycle ergometer exercise test was performed on 9 sprinters and 12 endurance runners, all in good national standing; 12 sedentary men served as control subjects. The relationship between VO2 and work-output appeared to be linear in most of t...
متن کاملInclusion of Exercise Intensities Above the Lactate Threshold in VO2/Running Speed Regression Does not Improve the Precision of Accumulated Oxygen Deficit Estimation in Endurance-Trained Runners.
The present study intended to verify if the inclusion of intensities above lactate threshold (LT) in the VO2/running speed regression (RSR) affects the estimation error of accumulated oxygen deficit (AOD) during a treadmill running performed by endurance-trained subjects. Fourteen male endurance-trained runners performed a sub maximal treadmill running test followed by an exhaustive supra maxim...
متن کاملDiscrepancy between training, competition and laboratory measures of maximum heart rate in NCAA division 2 distance runners.
A percentage of either measured or predicted maximum heart rate is commonly used to prescribe and measure exercise intensity. However, maximum heart rate in athletes may be greater during competition or training than during laboratory exercise testing. Thus, the aim of the present investigation was to determine if endurance-trained runners train and compete at or above laboratory measures of 'm...
متن کاملA study of cardio-pulmonary efficiency in different categories of runners.
Selected short distance runners, middle distance runners and long distance runners were subjected to graded exercise on a treadmill. The maximum aerobic power (VO2 max) and other indices related to oxygen transport system viz. heart rate, ventilation volume, breathing reserve, dyspnoeic index, O2 pulse and RQ were recorded at respective VO2 max work loads, and the values were compared. Long dis...
متن کاملWork-output Relationship of Runners during Graded Cycling Exercise: Sprinters vs. Endurance Runners
In order to study oxygen consumption (VO2) for a given work load at the exhaustive level of a graded cycling exercise in well-trained runners, a progressive cycle ergometer exercise test was performed on 9 sprinters and 12 endurance runners, all in good national standing; 12 sedentary men served as control subjects. The relationship between V02 and work-output appeared to be linear in most of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 10 1 شماره
صفحات -
تاریخ انتشار 2011