Generation of Parametric Image of Regional Myocardial Blood Flow Using H2O Dynamic PET and a Linear Least-Squares Method
نویسندگان
چکیده
Although a parametric image of myocardial blood flow (MBF) can be obtained from H2O PET using factor and cluster analysis, this approach is limited when factor analysis fails to extract each cardiac component. In this study, a linear least-squares (LLS) method for estimating MBF and generating a MBF parametric image was developed to overcome this limitation. The computer simulation was performed to investigate the statistical properties of the LLS method, and MBF values obtained from the MBF parametric images in dogs were compared with those obtained using the conventional region of interest (ROI) and invasive microsphere methods. Methods: A differential model equation for H2O in the myocardium was modified to incorporate the partial-volume and spillover effect. The equation was integrated from time 0 to each PET sampling point to obtain a linearlized H2O model equation. The LLS solution of this equation was estimated and used to calculate the MBF, the perfusable tissue fraction (PTF), and the arterial blood volume fraction (Va). A computer simulation was performed using the input function obtained from canine experiments and the tissue time– activity curves contaminated by various levels of Poisson noise. The parametric image of the MBF, PTF, and Va was constructed using the PET data from dogs (n 7) at rest and after pharmacologic stress. The regional MBF from the parametric image was compared with those produced by the ROI method using a nonlinear least-squares (NLS) estimation and an invasive radiolabeled microsphere technique. Results: The simulation study showed that the LLS method was better than the NLS method in terms of statistical reliability, and the parametric images of the MBF, PTF, and Va using the LLS method had good image quality and contrast. The regional MBF values using the parametric image showed a good correlation with those using the ROI method (y 0.84x 0.40; r 0.99) and the microsphere technique (y 0.95x 0.29; r 0.96). The computation time was approximately 10 s for the 32 32 6 18 (pixel pixel plane frame) matrix. Conclusion: A noninvasive, very fast, and accurate method for estimating the MBF and generating a MBF parametric image was developed using the LLS estimation technique and H2O dynamic myocardial PET.
منابع مشابه
Generation of parametric image of regional myocardial blood flow using H(2)(15)O dynamic PET and a linear least-squares method.
UNLABELLED Although a parametric image of myocardial blood flow (MBF) can be obtained from H(2)(15)O PET using factor and cluster analysis, this approach is limited when factor analysis fails to extract each cardiac component. In this study, a linear least-squares (LLS) method for estimating MBF and generating a MBF parametric image was developed to overcome this limitation. The computer simula...
متن کاملComparative assessment of parametric neuroreceptor mapping approaches based on the simplified reference tissue model using [¹¹C]ABP688 PET.
In recent years, several linearized model approaches for fast and reliable parametric neuroreceptor mapping based on dynamic nuclear imaging have been developed from the simplified reference tissue model (SRTM) equation. All the methods share the basic SRTM assumptions, but use different schemes to alleviate the effect of noise in dynamic-image voxels. Thus, this study aimed to compare those ap...
متن کاملComparison of Algorithms for Generating Parametric Image of Cerebral Blood Flow Using H2 O Positron Emission Tomography
Purpose: To obtain regional blood flow and tissue-blood partition coefficient with time-activity curves from H2 O PET, fitting of some parameters in the Kety model is conventionally accomplished by nonlinear least squares (NLS) analysis. However, NLS requires considerable compuation time then is impractical for pixel-by-pixel analysis to generate parametric images of these parameters. In this s...
متن کاملParametric imaging of myocardial blood flow with 15O-water and PET using the basis function method.
UNLABELLED Regional myocardial blood flow (MBF) can be measured with 15O-water and PET using the 1-tissue-compartment model with perfusable tissue fraction, which provides an MBF value that is free from the partial-volume effect. Studies with 15O-water have several advantages, such as the ability to repeat a scan. However, because of the short scanning time and the small distribution volume of ...
متن کاملEffect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET
Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...