Background/introduction To help improve therapeutic results for treatment of bone tumors, high intensity focused ultrasound (HIFU) is being investigated as a non-invasive alternative to surgery and radiotherapy. HIFU ablative treatments require an imaging modality for guidance, and magnetic resonance (MR) imaging is currently the strongest choice as it is able to provide temperature mapping throughout the treatment process. Unfortunately, the temperature feedback that is critical to ensuring safety and optimal soft tissue ablation is often unobtainable in bone structures. As an alternative to obtaining feedback, this project is focused on developing a simulator that is capable of predicting the temperature distribution in and around bone tissue during HIFU therapy. Having such a simulation would provide a better understanding of the thermal dosages incurred by the bone during HIFU treatment of tumors.
منابع مشابه
Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator
Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...
متن کاملRelationship between temperature and T2 in subcutaneous fat and bone marrow at 3T
Background/introduction MR-guided high-intensity focused ultrasound (HIFU) for treatment of uterine fibroids and painful bone metastases uses the proton resonant frequency shift (PRF) for temperature monitoring in water-based tissues. However, PRF fails to detect temperature changes in tissues with high lipid content, such as fat and bone marrow. Previous studies have shown a change in T2 of su...
متن کاملAn instrumented bone/soft tissue phantom designed to mimic HIFU treatments of bone
Background/introduction Clinically, HIFU exposures of bone are used to palliate pain from primary or secondary bone tumours. Such tumours weaken bone structure and render the patient susceptible to bone fracture. Ultrasound metrology for bone exposures is extremely challenging. The ultrasound beam is strongly reflected at the bone surface, with rapid surface absorption of sound entering the cor...
متن کاملA Numerical Investigation of the Time Reversal Mirror Technique for Trans-skull Brain Cancer Ultrasound Surgery
Introduction: The medical applications of ultrasound on human brain are highly limited by the phase and amplitude aberrations induced by the heterogeneities of the skull. However, it has been shown that time reversing coupled with amplitude compensation can overcome these aberrations. In this work, a model for 2D simulation of the time reversal mirror technique is proposed to study the possibil...
متن کاملThe relationship of T2WI signal intensity of uterine fibroids and the temperature curve in MR-guided high-intensity focused ultrasound (HIFU) ablation
Background/introduction MR guided high-intensity focused ultrasound (HIFU) ablation is increasingly being used worldwide to treat symptomatic uterine fibroids because of its excellent therapeutic efficacy in controlling symptoms and its excellent safety record. High signal intensity on T2WI MR images of fibroids is firstly considered a factor that induces poor ablation outcomes. Nevertheless, t...