An Evaluation of Ridge Extraction Methods for Portal Imaging
نویسندگان
چکیده
In this paper an existing ridge detector based on the Hessian tensor and a new one based on the structure tensor are evaluated for use in portal/simulator imaging. Tensor smoothing is introduced as a scaling parameter. By changing this scale (as opposed to the image scale) the detectors can be tuned to suppress spurious ridges without moving them. Desirable ridge detector properties for portal/simulator imaging are described and the ridge definitions are tested accordingly. Experiments show our new ridge detector to outperform the existing one in simulator/portal image matching.
منابع مشابه
Two Ridge Extraction Methods for Portal Imaging
In this paper an existing ridge detector based on the Hessian tensor and a new one based on the structure tensor are evaluated for use in portal/simulator imaging. Tensor smoothing is introduced as a scaling parameter. By changing this scale (as opposed to the image scale) the detectors can be tuned to suppress spurious ridges without moving them. Desirable ridge detector properties for portal/...
متن کاملEvaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy
Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...
متن کاملA quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...
متن کاملComparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کاملUtilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...