Evaluation of rectum and bladder dose accumulation from external beam radiotherapy and brachytherapy for cervical cancer using two different deformable image registration techniques
نویسندگان
چکیده
We evaluated dose-volume histogram (DVH) parameters based on deformable image registration (DIR) between brachytherapy (BT) and external beam radiotherapy (EBRT) that included a center-shielded (CS) plan. Eleven cervical cancer patients were treated with BT, and their pelvic and CS EBRT were studied. Planning CT images for EBRT and BT (except for the first BT, used as the reference image) were deformed with DIR to reference image. We used two DIR parameter settings: intensity-based and hybrid. Mean Dice similarity coefficients (DSCs) comparing EBRT with the reference for the uterus, rectum and bladder were 0.81, 0.77 and 0.83, respectively, for hybrid DIR and 0.47, 0.37 and 0.42, respectively, for intensity-based DIR (P < 0.05). D1 cm3 for hybrid DIR, intensity-based DIR and DVH addition were 75.1, 81.2 and 78.2 Gy, respectively, for the rectum, whereas they were 93.5, 92.3 and 94.3 Gy, respectively, for the bladder. D2 cm3 for hybrid DIR, intensity-based DIR and DVH addition were 70.1, 74.0 and 71.4 Gy, respectively, for the rectum, whereas they were 85.4, 82.8 and 85.4 Gy, respectively, for the bladder. Overall, hybrid DIR obtained higher DSCs than intensity-based DIR, and there were moderate differences in DVH parameters between the two DIR methods, although the results varied among patients. DIR is only experimental, and extra care should be taken when comparing DIR-based dose values with dose-effect curves established using DVH addition. Also, a true evaluation of DIR-based dose accumulation would require ground truth data (e.g. measurement with physical phantom).
منابع مشابه
Evaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملEvaluation of Volumetric Doses of Organs at Risk in Carcinoma Cervix Patients with HDR Intracavitary Brachytherapy and Comparison of CT-based and Conventional Plans
Background: Brachytherapy treatment planning in cervix carcinoma patients using two dimensional (2D) orthogonal images provides only point dose estimates while CT-based planning provides volumetric dose assessment helping in understanding the correlation between morbidity and the dose to organs at risk (OARs) and treatment volume. Objective: Aim of present study is to compare Internationa...
متن کاملMapping of dose distribution from IMRT onto MRI-guided high dose rate brachytherapy using deformable image registration for cervical cancer treatments: preliminary study with commercially available software
PURPOSE For patients undergoing external beam radiation therapy (EBRT) and brachytherapy, recommendations for target doses and constraints are based on calculation of the equivalent dose in 2 Gy fractions (EQD2) from each phase. At present, the EBRT dose distribution is assumed to be uniform throughout the pelvis. We performed a preliminary study to determine whether deformable dose distributio...
متن کاملAssessing cumulative dose distributions in combined radiotherapy for cervical cancer using deformable image registration with pre-imaging preparations
BACKGROUND The purpose of the study was to evaluate the feasibility of deformable image registration (DIR) in assessing cumulative dose distributions of the combination of external beam radiotherapy (EBRT) and fractionated intracavitary brachytherapy (ICBT) for cervical cancer. MATERIALS AND METHODS Three-dimensional image data sets of five consecutive patients were used. The treatment plan c...
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کامل