Hemodynamic effects of 15-mm-diameter microspheres on the rat pulmonary circulation

نویسندگان

  • ROBB W. GLENNY
  • SUSAN L. BERNARD
  • WAYNE J. LAMM
چکیده

Glenny, Robb W., Susan L. Bernard, and Wayne J. Lamm. Hemodynamic effects of 15-mm-diameter microspheres on the rat pulmonary circulation. J Appl Physiol 89: 499–504, 2000.—The microsphere method has been used extensively to measure regional blood flow in large laboratory animals. A fundamental premise of the method is that microspheres do not alter regional flow or vascular tone. Whereas this assumption is accepted in large animals, it may not be valid in the pulmonary circulation of smaller animals. Three studies were performed to determine the hemodynamic effects of microspheres on the rat pulmonary circulation. Increasing numbers of 15-mm-diameter microspheres were injected into a fully dilated, isolated-lung preparation. Vascular resistance increased 0.8% for every 100,000 microspheres injected. Microspheres were also injected into an isolated-lung preparation in which vascular tone was increased with hypoxia. Microspheres did not induce vasodilatation, as reported in other vascular beds. Fluorescent microspheres were injected via tail veins into awake rats, and the spatial locations of the microspheres were determined. Regional distributions remained highly correlated when microspheres of one color were injected after microspheres of another color. This indicates that the initial injection did not alter regional perfusion. We conclude that, when used in appropriate numbers, 15-mm-diameter microspheres do not alter regional flow or vascular tone in the rat pulmonary circulation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemodynamic effects of 15-microm-diameter microspheres on the rat pulmonary circulation.

The microsphere method has been used extensively to measure regional blood flow in large laboratory animals. A fundamental premise of the method is that microspheres do not alter regional flow or vascular tone. Whereas this assumption is accepted in large animals, it may not be valid in the pulmonary circulation of smaller animals. Three studies were performed to determine the hemodynamic effec...

متن کامل

Intravital microscopic observations of 15-microm microspheres lodging in the pulmonary microcirculation.

Vascular infusions of 15-microm-diameter microspheres are used to study pulmonary blood flow distribution. The sites of microsphere lodging and their effects on microvascular perfusion are debated but unknown. Using intravital microscopy of the subpleural surface of rat lungs, we directly observed deposition of fluorescent microspheres. In a pump-perfused lung model, approximately 0.5 million m...

متن کامل

Preparation of human serum albumin microspheres (MSA) kit for lung imaging in Iran [Persian]

Radiolabeled Microspheres of human serum albumin (MSA) is of great importance in the analysis of regional lung perfusion. Preparation of MSA kit has been installed in our Division recently is carried out in two stages: 1. Production of albumin sphere particles with suitable sizes by using the spinning disk technique. 2. Formulation of MSA as a radiopharmacutical kit. So it can be labelled...

متن کامل

Effects of acetylsalicylic acid on the ductus arteriosus and circulation in fetal lambs in utero.

Intra-arterial and intravenous catheters were inserted in six fetal lambs at 125-130 days of gestation. On the following day, fetal arterial pressures and blood gases were monitored and fetal cardiac output and its distribution were measured by injection of radionuclide-labeled microspheres 15 mum in diameter. Acetylsalicylic acid, 55-90 mg/kg of estimated fetal weight, then was administered in...

متن کامل

The relationship between intrahepatic portal systemic shunts and microsphere induced portal hypertension in the rat liver.

BACKGROUND Portal hypertension is associated with gross haemodynamic disturbances characterised by high cardiac output, low peripheral vascular resistance, increased splanchnic blood flow, and portal systemic shunting. AIMS To study the relationship between intrahepatic portal systemic shunts and microsphere induced portal hypertension in the rat liver. METHODS Different sized microspheres ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000