Volumetric computerized tomography as a measurement of periprosthetic acetabular osteolysis and its correlation with wear
نویسندگان
چکیده
Osteolysis, which is considered to be a major source of morbidity following total hip joint replacement, has been notoriously difficult to measure accurately, particularly in the acetabular area. In order to study periacetabular osteolysis, specialized software for computerized tomography (CT) scan image analysis has been developed. This software (3D-CT) eliminates metal artifacts, allows three-dimensional segmentation of the CT image, and reconstructs the segmented image to provide an accurate representation and measurement of volume for osteolytic lesions. In the present study, 20 patients underwent periacetabular osteolytic volume determination using 3D-CT, functional assessment (using the Harris Hip Scale, the Western Ontario and McMaster University Osteoarthritis Index, and the short form 36 questionnaire), and two-dimensional analysis of volumetic polyethylene wear using digitalized plain films. Periacetabular osteolysis correlated directly with the polyethylene wear rate (relative risk [RR] = 0.494, P = 0.027). If one patient with an acetabular revision, one patient with recurrent dislocation, and one patient with a Biomet prosthesis are excluded, then the correlation between wear and osteolysis is improved (RR = 0.685, P = 0.002). In summary, the current study demonstrates both the feasibility of CT imaging of periacetabular osteolysis and the correlation between polyethylene wear and osteolytic volume, providing a potential outcome measure for clinical trials that are designed to examine interventions in this complex disease process.
منابع مشابه
The Usefulness of Three-dimensional Computed Tomography as an Assessment of Periacetabular Osteolysis in Revision Total Hip Arthroplasty
PURPOSE This study was performed to determine the usefulness of three-dimensional computed tomography (3D-CT) in measuring periacetabular osteolysis by comparing the real volume of osteolysis in revision surgery. MATERIALS AND METHODS Twnety-three patients who had undergone revision surgery due to periacetabular osteolysis but not included septic osteolysis and implant loosening. The mean age...
متن کاملBackside volumetric change in the polyethylene of uncemented acetabular components.
Polyethylene wear of acetabular components is a key factor in the development of periprosthetic osteolysis and wear at the articular surface has been well documented and quantified, but fewer data are available about changes which occur at the backside of the liner. At revision surgery for loosening of the femoral component we retrieved 35 conventional modular acetabular liners of the same desi...
متن کاملHOJ-2003 v7
William H. Harris, M.D. Alan Gerry Clinical Professor of Orthopaedic Surgery Director of Orthopaedic Biomechanics and Biomaterials Laboratory Massachusetts General Hospital 55 Fruit Street, GRJ 1126 Boston, MA 02114 (617) 724-0526 (voice) (617) 726-3883 (fax) [email protected] INTRODUCTION A widely held concept suggests that there is an acceptable threshold, or lower limit, of particle ...
متن کاملPeriprosthetic osteolysis and its association with RANKL expression.
Extensive osteolysis adjacent to orthopedic implants is often associated with wear particles of prosthetic material. The activation of the RANKL/RANK/OPG system is considered to be a likely cause of periprosthetic osteolysis leading to implant failure. The aim of this study was to examine the possible correlation between the clinical extent of osteolysis, the number of wear particles and expres...
متن کاملDenosumab for treating periprosthetic osteolysis; study protocol for a randomized, double-blind, placebo-controlled trial.
BACKGROUND Wear-induced osteolysis is the main factor in reducing the longevity of total hip arthroplasty (THA). The transmembrane Receptor Activator of Nuclear Factor κ B (RANK) and its corresponding ligand RANKL is an important regulator of osteoclast activity and bone resorption and is associated with osteolysis around implant. Inhibiting RANKL with denosumab is effective in vivo in preventi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arthritis Research
دوره 4 شماره
صفحات -
تاریخ انتشار 2002