Fentanyl uptake by the scimed membrane oxygenator.
نویسندگان
چکیده
With the initiation of cardiopulmonary bypass (CPB), using a membrane oxygenator, the drop in circulating fentanyl concentration is greater than can be attributed to dilution alone. This study examined the Scimed brand (2A-800) membrane oxygenator as a site of fentanyl binding. Initial experiments used an assembled CPB circuit. Subsequent dissection and analysis of the oxygenator revealed that the silicone-based membrane sheets were the primary site of fentanyl binding. The silicone-containing waterproof wrapper was also responsible for 1% to 2% of fentanyl binding. Binding of fentanyl to the Scimed membrane oxygenator occurs at a rapid rate and continues until the membrane has taken up 130 ng/cm2 of membrane surface area. The interaction is complete by 15 to 30 minutes if suprasaturated concentrations are used. Samples of membrane material with a surface area of 1 cm2 were also studied. Isolated membrane squares in a nonmoving prime solution required two hours for saturation at the same fentanyl concentrations as the intact membrane with circulating prime. Introduction of motion to the priming solution accelerated the rate of fentanyl binding by the isolated membrane squares to a rate similar to the intact membrane. Motion also provided results similar to those previously reported using different analysis techniques. Therefore, this method of studying fentanyl-membrane interactions using samples of membrane and tritiated fentanyl is a valid model for the intact membrane oxygenator in the assembled bypass circuit. In addition to solution movement, fentanyl concentration of the priming solution was also found to affect the rate of fentanyl uptake. When fentanyl concentrations were used which were insufficient to achieve saturation of the membrane (10 ng/mL and 20 ng/mL), the rate of uptake was slowed. Binding of all available fentanyl under these conditions occurred within three hours. There is potential modification of this interaction by several clinically relevant factors, including temperature, pH, protein content of prime solution, and other drugs. These areas require further study before the saturation data are applied to clinical practice.
منابع مشابه
In vitro variability in fentanyl absorption by different membrane oxygenators.
The membrane oxygenator has replaced the bubble oxygenator in a wide variety of clinical settings. The membrane oxygenators now manufactured can be grouped into three categories based on composition and design: (1) silicone with a true membrane structure; (2) polypropylene with a microporous sheet; and (3) polypropylene with a microtubular structure. The capacity for fentanyl uptake by membrane...
متن کاملIn vitro drug adsorption and plasma free hemoglobin levels associated with hollow fiber oxygenators in the extracorporeal life support (ECLS) circuit.
The purpose of this study was to identify the percentage of fentanyl or morphine sulfate lost from adhesion to either the polyvinylchloride (PVC) tubing or the surface of two different hollow fiber oxygenators used in current extracorporeal life support circuits and to identify any difference in the plasma free hemoglobin (PFH) levels generated when using these oxygenator and/or drug combinatio...
متن کاملIn vivo uptake and elimination of isoflurane by different membrane oxygenators during cardiopulmonary bypass.
BACKGROUND Volatile anesthetics are frequently used during cardiopulmonary bypass (CPB) to maintain anesthesia. Uptake and elimination of the volatile agent are dependent on the composition of the oxygenator. This study was designed to evaluate whether the in vivo uptake and elimination of isoflurane differs between microporous membrane oxygenators containing a conventional polypropylene (PPL) ...
متن کاملChanges in sevoflurane plasma concentration with delivery through the oxygenator during on-pump cardiac surgery.
BACKGROUND It is unclear what factors affect the uptake of sevoflurane administered through the membrane oxygenator during cardiopulmonary bypass (CPB) and whether this can be monitored via the oxygenator exhaust gas. METHODS Stable delivery of sevoflurane was administered to 30 elective cardiac surgery patients at 1.8 vol% (inspiratory) via the anaesthetic circuit and ventilator. During CPB,...
متن کاملAn In Vitro Comparison of Micro Air Passage in the Venous Reservoir Bag
_____________ _ The increasing use of membrane oxygenators and collapsable venous reservoir bags (VRB) imposes a concern not associated with bubble oxygenators: Venous line air. Since no defoamer is present, a VRB must rely on flow characteristics or a barrier to remove air from the venous return. The purpose of this study is to determine the air removal efficiency of seven commercially availab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiothoracic anesthesia
دوره 2 5 شماره
صفحات -
تاریخ انتشار 1988