In vivo quantitative tissue characterization of human coronary arterial plaques by use of integrated backscatter intravascular ultrasound and comparison with angioscopic findings.

نویسندگان

  • Masanori Kawasaki
  • Hisato Takatsu
  • Toshiyuki Noda
  • Keiji Sano
  • Yoko Ito
  • Kenji Hayakawa
  • Kunihiko Tsuchiya
  • Masazumi Arai
  • Kazuhiko Nishigaki
  • Genzou Takemura
  • Shinya Minatoguchi
  • Takako Fujiwara
  • Hisayoshi Fujiwara
چکیده

BACKGROUND The purpose of the present study was to define whether integrated backscatter (IB) combined with conventional intravascular ultrasound (IVUS) makes tissue characterization of coronary arterial plaques possible. METHODS AND RESULTS IB-IVUS was performed in coronary arteries (total 18 segments) of 9 patients at autopsy, and the findings were compared with the histology. RF signals, which were digitized at 2 GHz in 8-bit resolution, were obtained with an IVUS system with a 40-MHz catheter. IB values of the RF signal from the region of interest (ROI) (100-microm depth, 1.4 degrees per line) were calculated by use of a personal computer. IB values on the ROIs were divided into 5 categories, compared with each of the plaque histologies: category 1 (thrombus), -88 < IB < or = -80; category 2 (intimal hyperplasia or lipid core), -73 < IB < or = -63; category 3 (fibrous tissue), -63 < IB < or = -55; category 4 (mixed lesions), -55 < IB < or = -30; and category 5 (calcification), -30 < IB < or = -23. On the basis of these categories, we analyzed 5120 ROIs per segment in each ring-like arterial specimen. Color-coded maps of plaques were constructed by use of these IB data and conventional IVUS data, which reflected the plaque histology of autopsied coronary arteries well. Then, the same method was undertaken in 24 segments with plaque from 12 patients in vivo with angina pectoris. Comparisons between coronary angioscopy and IB-IVUS revealed that the surface color of plaques in angioscopy reflected the thickness of the fibrous cap rather than the size of the lipid core. CONCLUSIONS IB-IVUS represents a new and useful tool for evaluating the tissue structure of human coronary arterial plaques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated Backscatter Intravascular Ultrasound

About 30 years ago, a pathological study by Horie et al. demonstrated that plaque rupture into the lumen of a coronary artery may precede and cause thrombus formation leading to acute myocardial infarction (Horie et al., 1978). In an angioscopic study, Mizuno et al. demonstrated that disruption or erosion of vulnerable plaques and subsequent thromboses are the most frequent cause of acute coron...

متن کامل

Intravascular Imaging and Vulnerable Plaque olumetric Quantitative Analysis of issue Characteristics of Coronary Plaques fter Statin Therapy Using Three-Dimensional ntegrated Backscatter Intravascular Ultrasound

OBJECTIVES The purpose of the present study was twofold: 1) to evaluate the usefulness of threedimensional (3D) integrated backscatter (IB) intravascular ultrasound (IVUS) for quantitative tissue characterization of coronary plaques; and 2) to use this imaging technique to determine if six months of statin therapy alters the tissue characteristics of coronary plaques. BACKGROUND Three-dimension...

متن کامل

Diagnostic accuracy of optical coherence tomography and integrated backscatter intravascular ultrasound images for tissue characterization of human coronary plaques.

OBJECTIVES The purpose of the present study was to validate the diagnostic accuracy of optical coherence tomography (OCT), integrated backscatter intravascular ultrasound (IB-IVUS), and conventional intravascular ultrasound (C-IVUS) for tissue characterization of coronary plaques and to evaluate the advantages and limitations of each of these modalities. BACKGROUND The diagnostic accuracy of ...

متن کامل

Distribution of ultrasonic radiofrequency signal amplitude detects lipids in atherosclerotic plaque of coronary arteries: an ex-vivo study

BACKGROUND Accumulation of lipids within coronary plaques is an important process in disease progression. However, gray-scale intravascular ultrasound images cannot detect plaque lipids effectively. Radiofrequency signal analysis could provide more accurate information on preclinical coronary plaques. METHODS We analyzed 29 zones of mild atheroma in human coronary arteries acquired at autopsy...

متن کامل

In vivo quantitative tissue characterization of angiographically normal coronary lesions and the relation with risk factors: a study using integrated backscatter intravascular ultrasound.

BACKGROUND Autopsy studies have shown atherosclerotic changes in angiographically normal coronary lesions (ANCL), and conventional intravascular ultrasound shows intimal thickening in these lesions, but cannot differentiate the lipid core. Accurate characterization of ANCL is essential to prevent progression to coronary artery disease. METHODS AND RESULTS ANCL (n=120) were analyzed by integra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 105 21  شماره 

صفحات  -

تاریخ انتشار 2002