Distortion-Product Otoacoustic Emissions: Body Position Effects with Simultaneous Presentation of Tone Pairs
نویسندگان
چکیده
This study examined the effect of three different body positions on distortion-product otoacoustic emission (DPOAE) amplitude and noise levels with multiple primary tone pairs simultaneously-presented to 36 normal-hearing female human adults. Other studies have demonstrated that the simultaneously presented tone pairs method shows clinical promise as a screener, but the sequential method remains in widespread clinical use. Postural changes have been suggested to have an effect not only on DPOAEs, but also transient-evoked OAEs and stimulus-frequency OAEs. DPOAE amplitude and noise levels were recorded in seated, supine, and side-lying positions to the following order of simultaneously-presented tone pairs relative to the f2 frequencies: 1187, 2375, and 4812 Hz; 1500, 3000, and 6062 Hz; and 1875, 3812, and 7625 Hz. No DPOAE could be detected reliably at 7625 Hz as result of poor signal-to-noise ratio. For remaining DPOAEs, statistical analyses revealed that amplitudes were not significantly different among the three body positions. However, at 1500 Hz and below, body position did have a statistically significant effect on noise levels though they are likely clinically negligible. Except at 7625 Hz, results suggest that DPOAEs recorded using a simultaneously presented tone pairs appear to be comparably recorded regardless of an individual's body position.
منابع مشابه
Distortion product otoacoustic emissions to single and simultaneous tone pairs.
Distortion product otoacoustic emissions (DPOAEs) evoked by single tone pairs and three simultaneous tone pairs were recorded in 60 normal-hearing adult ears. The purpose was to replicate a previous study using the commercially available probe assembly of the Grason Stadler GSI 60 and including ear of presentation in the statistical analysis along with frequency and condition. DPOAE levels were...
متن کاملDistortion product otoacoustic emissions: comparison of sequential versus simultaneous presentation of primary-tone pairs.
This Grason-Stadler GSI-60 system for measuring distortion product otoacoustic emissions (DPOAEs) allows the examiner to present one set of primary-tone pairs at a time (i.e., sequential presentation), or to present as many as four sets of primary-tone pairs at a time (i.e., simultaneous presentation). The Sequential and Simultaneous protocols were used to compare administration times, DPOAEs, ...
متن کاملThe effects of body position on distortion-product otoacoustic emission testing.
Otoacoustic emissions are frequently acquired from patients in a variety of body positions aside from the standard, seated orientation. Yet little knowledge is available regarding whether these deviations will produce nonpathological changes to the clinical results obtained. The present study aimed to describe the effects of body position on the distortion-product otoacoustic emissions of 60 no...
متن کاملThe audiological profile of adults with and without hypertension
OBJECTIVE To determine whether there is any influence of systemic arterial hypertension on the peripheral auditory system. METHODS This was a cross-sectional study that investigated 40 individuals between 30 and 50 years old, who were divided into groups with and without systemic arterial hypertension, using data from high-frequency audiometry, transient-evoked otoacoustic emissions and disto...
متن کاملEffects of a suppressor tone on distortion product otoacoustic emissions fine structure: why a universal suppressor level is not a practical solution to obtaining single-generator DP-grams.
OBJECTIVES The use of a suppressor tone has been proposed as the method of choice in obtaining single-generator distortion product (DP) grams, the speculation being that such DP grams will be more predictive of hearing thresholds. Current distortion product otoacoustic emissions (DPOAE) theory points to the ear canal DPOAE signal being a complex interaction between multiple components. The effe...
متن کامل