Using CorvisST tonometry to assess glaucoma progression
نویسندگان
چکیده
PURPOSE To investigate the utility of the Corneal Visualization Scheimpflug Technology instrument (CST) to assess the progression of visual field (VF) damage in primary open angle glaucoma patients. METHOD A total of 75 eyes from 111 patients with primary open-angle glaucoma were investigated. All patients underwent at least nine VF measurements with the Humphrey Field Analyzer, CST measurements, axial length (AL), central corneal thickness (CCT) and intraocular pressure (IOP) with Goldmann applanation tonometry (GAT). Mean total deviation (mTD) progression rates of the eight VFs, excluding the first VF, were calculated and the association between progression rate and the other listed measurements was analyzed using linear regression, and the optimal to describe mTD progression rate was selected based on the second order bias corrected Akaike Information Criterion (AICc) index. RESULTS VF progression was described best in a model that included CST parameters as well as other ocular measurements. The optimal linear model to describe mTD progression rate was given by the equation: -8.9-0.068 x mean GAT + 0.68 x A1 time + 0.31 x A2 time -0.39 x A2 length- 1.26 x highest deformation amplitude. CONCLUSION CST measurements are useful when assessing VF progression in glaucoma patients. In particular, careful consideration should be given to patients where: (i) an eye is observed to be applanated fast in the first and second applanations, (ii) the applanated area is wide in the second applanation and (iii) the indentation is deep at the maximum deformation, since these eyes appear to be at greater risk of VF progression.
منابع مشابه
The usefulness of CorvisST Tonometry and the Ocular Response Analyzer to assess the progression of glaucoma
Corneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s with the Humphrey Field Analyzer. VF progression was...
متن کاملAssociation between Corneal Biomechanical Properties with Ocular Response Analyzer and Also CorvisST Tonometry, and Glaucomatous Visual Field Severity
PURPOSE To investigate the association between corneal biomechanical properties measured with the Ocular Response Analyzer (ORA) and also CorvisST (CST) tonometry, and glaucomatous visual field (VF) severity. METHODS One hundred forty-six eyes of 91 patients with primary open-angle glaucoma who performed Humphrey Field Analyzer 30-2 or 24-2 SITA-Standard, ORA, and CST within 180 days were inc...
متن کاملThe Effect of Corneal Refractive Surgery on Glaucoma
Laser-assisted refractive procedures have become very popular in the last two decades. As a result, a "generation" of patients with altered corneal properties is emerging. These patients will require both cataract extraction and glaucoma follow-up in the future. Since the glaucoma examination largely depends on the corneal properties, the reshaped postrefractive surgery cornea poses a challenge...
متن کاملRole of corneal thickness in glaucoma incidence and progression becoming clearer
CORNEAL thickness may not only affect IOP measurements performed with Goldmann applanation tonometry (GAT) but may also be linked to the aetiology of glaucoma itself. However, there is no practical or reliable means at present to adjust IOP measurements in individual patients for variations in corneal thickness, James Brandt MD, professor of ophthalmology and director, glaucoma service, Univers...
متن کاملComparison of Ocular Pulse Amplitude Lowering Effects of Preservative-Free Tafluprost and Preservative-Free Dorzolamide-Timolol Fixed Combination Eyedrops
PURPOSE To compare the ocular pulse amplitude (OPA) lowering effects of preservative-free tafluprost and dorzolamide-timolol fixed combination (DTFC) using dynamic contour tonometry. METHODS In total, 66 eyes of 66 patients with normal tension glaucoma (NTG) (n = 34) or primary open angle glaucoma (POAG) (n = 32) were included. Patients were divided into two groups: the preservative-free tafl...
متن کامل