Accelerating global left-ventricular function assessment in mice using reduced slice acquisition and three-dimensional guide-point modelling

نویسندگان

  • Alistair A Young
  • Debra J Medway
  • Craig A Lygate
  • Stefan Neubauer
  • Jürgen E Schneider
چکیده

BACKGROUND To investigate the utility of three-dimensional guide-point modeling (GPM) to reduce the time required for CMR evaluation of global cardiac function in mice, by reducing the number of image slices required for accurate quantification of left-ventricular (LV) mass and volumes. METHODS Five female C57Bl/6 mice 8 weeks post myocardial infarction induced by permanent occlusion of the left coronary artery, and six male control (un-operated) C57Bl/6 mice, were subject to CMR examination under isoflurane anaesthesia. Contiguous short axis (SAX) slices (1 mm thick 7-9 slices) were obtained together with two long axis (LAX) slices in two chamber and four chamber orientations. Using a mathematical model of the heart to interpolate information between the available slices, GPM LV mass and volumes were determined using full slice (all SAX and two LAX), six slice (four SAX and two LAX) and four slice (two SAX and two LAX) analysis protocols. All results were compared with standard manual volumetric analysis using all SAX slices. RESULTS Infarct size was 39.1±5.1% of LV myocardium. No significant differences were found in left ventricular mass and volumes between the standard and GPM full and six slice protocols in infarcted mice (113±10, 116±11, and 117±11 mg respectively for mass), or between the standard and GPM full, six and four slice protocols in control mice, (105±14, 106±10, 104±12, and 105±7 mg respectively for mass). Significant differences were found in LV mass (135±18 mg) and EF using the GPM four slice protocol in infarcted mice (p<0.05). CONCLUSION GPM enables accurate analysis of LV function in mice with relatively large infarcts using a reduced six slice acquisition protocol, and in mice with normal/symmetrical left-ventricular topology using a four slice protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of global and regional left ventricular function and volumes with 64-slice multi-slice computed tomography: a comparison with 2D echocardiography

Introduction: In patients with coronary artery disease (CAD), LV function and volumes are important parameters for long-term prognosis. 64-slice MSCT allows non-invasive assessment of the coronary arteries, but the accuracy of 64-slice MSCT for assessment of LV volumes and function is unknown. Methods: A head-to-head comparison between 64-slice MSCT and 2D echocardiography was performed in 40 p...

متن کامل

Doppler-Derived Myocardial Performance Index in Healthy Children in Shiraz

Background: Assessment of myocardial function is essential in heart disease, but in regard to systolic and diastolic functions such evaluation has limitation. Ejection fraction is difficult to assess in abnormally-shaped ventricles, and diastolic inflow velocity pattern may be fused because of tachycardia. Objective: A myocardial performance index (MPI) or Tei index has been developed for adult...

متن کامل

Early assessment of percutaneous coronary interventions for chronic total occlusions analyzed by novel echocardiographic techniques

OBJECTIVE Successful revascularization of chronic total occlusions has been associated with improved left ventricular systolic function, reduced anginal symptoms, increased exercise capacity, and increased survival. This study was conducted to determine the impact of revascularization in chronic total occlusion on left ventricular function using novel echocardiographic techniques. METHODS A t...

متن کامل

Assessment of Left Ventricular Function and Hemodynamics using Three-dimensional Echocardiography

................................................................................................................................. iii LIST OF PUBLICATIONS ......................................................................................................... v DIVISION OF WORK BETWEEN AUTHORS ..................................................................... vii SCIENTIFIC CONTRIBUTIONS NO...

متن کامل

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 13  شماره 

صفحات  -

تاریخ انتشار 2011