Bioprosthetic Mitral Valve Regurgitation

نویسندگان

  • Byron F. Vandenberg
  • Krishnan B. Chandran
  • Richard E. Kerber
چکیده

The usefulness of two-dimensional color-Doppler flow-imaging (2D Doppler) in the detection, localization, and quantitation of bioprosthetic mitral valve regurgitation is uncertain. Mitral bioprostheses, before and after the creation of transvalvular (n = 33), paravalvular (n = 17), or combined (n = 23) defects, were mounted in a pulsed duplication system (flow rates, 2.5-6.5 1/min; pulse rate, 70 beats/min). An Aloka 880 2D Doppler system (Japan) was used to image the regurgitant jets in the simulated left atrial chamber, analogous to images obtained with transesophageal echocardiography. Jet area was corrected to an estimate of stroke volume: 2D Doppler measurements were divided by [(valve effective orifice area) x (continuous-wave Doppler-determined mean diastolic filling velocity)]/pulse rate. Regurgitant fraction and regurgitant volume were measured by an electromagnetic flow probe. 2D Doppler correctly identified the presence and location of paravalvular regurgitation. In transvalvular and combined transvalvular-paravalvular defects, there were six incorrect interpretations, all having transvalvular regurgitant volumes less than 4 mi/beat. In the presence oftransvalvular regurgitation, jet area, length, and width correlated linearly with regurgitant volume (r= 0.82, 0.80, and 0.68, respectively; p<0.0001) and regurgitant fraction (r=0.62, 0.61, and 0.45, respectively; p<0.001). Correlations with regurgitant fraction

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimally Invasive Mitral Valve Replacement Using the Valve-in-valve Technique.

A 90-year-old woman with two previous mitral valve replacements, presented with pulmonary edema due to mitral regurgitation from degeneration of her bioprosthetic mitral valve. A minimally invasive approach was used to replace the bioprosthetic mitral valve. During surgery, the bioprosthetic valve was noted to be too adherent to the endocardium of the left atrium, making removal of the prosthes...

متن کامل

Long-term clinical evaluation of mitral valve replacement with porcine bioprosthetic valves in dogs.

This study evaluated the long-term clinical performance of newly developed porcine bioprosthetic valves cross-linked with glutaraldehyde and polyepoxy compound for mitral valve replacement (MVR) in dogs. Five beagle dogs underwent MVR using the porcine bioprosthetic valves during cardiopulmonary bypass. Antithrombotic drugs were administered only for one month after MVR. Six months after MVR, t...

متن کامل

Transvenous, antegrade Melody valve-in-valve implantation for bioprosthetic mitral and tricuspid valve dysfunction: a case series in children and adults.

OBJECTIVES The purpose of this study was to report the results of percutaneous valve-in-valve therapy using the Melody valve (Medtronic, Minneapolis, Minnesota) for patients with degenerated mitral and tricuspid bioprosthetic valves. BACKGROUND Open surgery for replacement of degenerated bioprosthetic valves is associated with morbidity and mortality. METHODS Nineteen patients (median age 6...

متن کامل

Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...

متن کامل

Bioprosthetic mitral valve thrombosis less than one year after replacement and an ablative MAZE procedure: a case report

Occurrence of bioprosthetic valve thrombosis less than a year after replacement is very uncommon. Here, we describe a case of a 57 year old male, who presented 10 months after receiving a bioprosthetic mitral valve replacement with a two week history of dyspnea on exertion, worsening orthopnea and decreased exercise tolerance. Echocardiography revealed severe mitral regurgitation (MR), thrombos...

متن کامل

Use of Cardiac Computerized Tomography to Predict Neo–Left Ventricular Outflow Tract Obstruction Before Transcatheter Mitral Valve Replacement

A lthough the incidence of mitral stenosis has declined precipitously in the Western world due to the reduced incidence of rheumatic heart disease, mitral regurgitation remains one of the most common valvular pathologies. Many patients affected by severe mitral valve disease are elderly with multiple comorbidities and are at high risk for traditional open surgical mitral valve repair or replace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005