Indoor thermal factors and symptoms in office workers: findings from the US EPA BASE study.
نویسندگان
چکیده
UNLABELLED Some prior research in office buildings has associated higher indoor temperatures even within the recommended thermal comfort range with increased worker symptoms. We reexamined this relationship in data from 95 office buildings in the US Environmental Protection Agency's Building Assessment Survey and Evaluation Study. We investigated relationships between building-related symptoms and thermal metrics constructed from real-time measurements. We estimated odds ratios and 95% confidence intervals in adjusted logistic regression models with general estimating equations, overall and by season. Winter indoor temperatures spanned the recommended winter comfort range; summer temperatures were mostly colder than the recommended summer range. Increasing indoor temperatures, overall, were associated with increases in few symptoms. Higher winter indoor temperatures, however, were associated with increases in all symptoms analyzed. Higher summer temperatures, above 23 degrees C, were associated with decreases in most symptoms. Humidity ratio, a metric of absolute humidity, showed few clear associations. Thus, increased symptoms with higher temperatures within the thermal comfort range were found only in winter. In summer, buildings were overcooled, and only the higher observed temperatures were within the comfort range; these were associated with decreased symptoms. Confirmation of these findings would suggest that thermal management guidelines consider health effects as well as comfort, and that less conditioning of buildings in both winter and summer may have unexpected health benefits. PRACTICAL IMPLICATIONS In winter, higher temperatures within the thermal comfort range are common in US office buildings and may be associated with increased symptoms. In summer, temperatures below the thermal comfort range are common and may be associated with increased symptoms. Results from this large study thus suggest that in US office buildings, less winter heating (in buildings that are in heating mode) and less summer cooling may reduce acute symptoms while providing substantial energy conservation benefits, with no expected thermal comfort penalty and, in summer, even thermal comfort benefits. If confirmed, this would be welcome news.
منابع مشابه
Indoor Carbon Dioxide Concentrations and Sbs in Office Workers
Relationships between indoor carbon dioxide (CO2) levels and mucous membrane and lower respiratory sick building syndrome (SBS) symptoms are explored in 41 office buildings from the US EPA BASE study. Elevated indoor CO2 concentrations may indicate inadequate ventilation per occupant and elevated indoor pollutant concentrations, leading to SBS symptoms. Two CO2 metrics were constructed: average...
متن کاملمطالعه علائم سندرم ساختمان بیمار در کارکنان اداری سازمان بهداشت و درمان صنعت نفت
Background­ and objectives : Research has consistently shown that air quality personal factors and work related factors were the most effective parameters for sick building syndrome. Several epidemiological studies have been carried out to show the prevalence of the sick building syndrome among the office workers but less attention has been paid to the relation of the sick building s...
متن کاملSarcoidosis, asthma, and asthma-like symptoms among occupants of a historically water-damaged office building.
UNLABELLED Sarcoidosis is a granulomatous disease of unknown etiology with evidence of association with exposure to microbial agents. In June 2006, we investigated a sarcoidosis cluster among office workers in a water-damaged building. In the course of the investigation, we became aware of a high rate of respiratory complaints including asthma and asthma-like symptoms. We conducted case finding...
متن کاملInvestigating the Effects of Environmental Factors on Office Buildings’ Indoor Environment Quality in Iran’s Cold Climate (Case study: Kermanshah)
The inappropriate indoor environmental quality of a building causes different problems such asheadache and breathing difficulties which are called the syndrome of building sickness. These diseases reduce the efficiency of people and deteriorate the quality of their life. Studies carried out in hundreds of big office buildings across the world show that the indoor environment qualities of these ...
متن کاملAssessment of VOCs, PM10, and Formaldehyde Exposure in the Hair Salons of South Korea
Introduction: In hair salons, workers and customers are exposed to high concentrations of several chemical compounds used during the working environment. Volatile Organic Compounds (VOCs), particulate matter (PM10), nitrogen dioxide (NO2), sulfur dioxide (SO2), carbon monoxide (CO), and formaldehyde are the major chemicals that alter the indoor air quality. This study aimed to assess the indoor...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Indoor air
دوره 19 4 شماره
صفحات -