On the property of measurements with the PTW microLion chamber in continuous beams.

نویسندگان

  • Jonas Andersson
  • Erik Johansson
  • Heikki Tölli
چکیده

PURPOSE The performance of liquid ionization chambers, which may prove to be useful tools in the field of radiation dosimetry, is based on several chamber and liquid specific characteristics. The present work investigates the performance of the PTW microLion liquid ionization chamber with respect to recombination losses and perturbations from ambient electric fields at various dose rates in continuous beams. METHODS In the investigation, experiments were performed using two microLion chambers, containing isooctane (C(8)H(18)) and tetramethylsilane [Si(CH(3))(4)] as the sensitive media, and a NACP-02 monitor chamber. An initial activity of approximately 250 GBq (18)F was employed as the radiation source in the experiments. The initial dose rate in each measurement series was estimated to 1.0 Gy min(-1) by Monte Carlo simulations and the measurements were carried out during the decay of the radioactive source. In the investigation of general recombination losses, employing the two-dose-rate method for continuous beams, the liquid ionization chambers were operated at polarizing voltages 25, 50, 100, 150, 200, and 300 V. Furthermore, measurements were also performed at 500 V polarizing voltage in the investigation of the sensitivity of the microLion chamber to ambient electric fields. RESULTS The measurement results from the liquid ionization chambers, corrected for general recombination losses according to the two-dose-rate method for continuous beams, had a good agreement with the signal to dose linearity from the NACP-02 monitor chamber for general collection efficiencies above 70%. The results also displayed an agreement with the theoretical collection efficiencies according to the Greening theory, except for the liquid ionization chamber containing isooctane operated at 25 V. At lower dose rates, perturbations from ambient electric fields were found in the microLion chamber measurement results. Due to the perturbations, measurement results below an estimated dose rate of 0.2 Gy min(-1) were excluded from the present investigation of the general collection efficiency. The perturbations were found to be more pronounced when the chamber polarizing voltage was increased. CONCLUSIONS By using the two-dose-rate method for continuous beams, comparable corrected ionization currents from experiments in low and medium energy photon beams can be achieved. However, the valid range of general collection efficiencies has been found to vary in a comparison between experiments performed in continuous beams of 120 kVp x ray, and the present investigation of 511 keV annihilation photons. At very high dose rates in continuous beams, there are presently no methods that can be used to correct for general recombination losses and at low dose rates the microLion chamber may be perturbed by ambient electric fields. Increasing the chamber polarizing voltage, which diminishes the general recombination effect, was found to increase the microLion chamber sensitivity to ambient electric fields. Prudence is thus advised when employing the microLion chamber in radiation dosimetry, as ambient electric fields of the strength observed in the present work may be found in many common situations. Due to uncertainties in the theoretical basis for recombination losses in liquids, further studies on the underlying theories for the initial and general recombination effect are needed if liquid ionization chambers are to become a viable option in high precision radiation dosimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical radiation therapy measurements with a new commercial synthetic single crystal diamond detector

A commercial version of a synthetic single crystal diamond detector (SCDD) in a Schottky diode configuration was recently released as the new type 60019 microDiamond detector (PTW-Freiburg, Germany). In this study we investigate the dosimetric properties of this detector to independently confirm that findings from the developing group of the SCDDs still hold true for the commercial version of t...

متن کامل

Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator

Most modern radiation therapy devices allow the use of very small fields, either through beamlets in Intensity-Modulated Radiation Therapy (IMRT) or via stereotactic radiotherapy where positioning accuracy allows delivering very high doses per fraction in a small volume of the patient. Dosimetric measurements on medical accelerators are conventionally realized using air-filled ionization chambe...

متن کامل

Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731

Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter    of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...

متن کامل

Small photon field dosimetry using EBT2 Gafchromic film and Monte Carlo simulation

Background: Small photon fields are increasingly used in modern radiotherapy especially in intensity modulated radiation therapy (IMRT) and stereotactic radiosurgery (SRS) treatments. Accurate beam profile and central axis depth doses measurements of such beams are complicated due to the electron disequilibrium. Hence the EBT2 (external beam therapy) Gafchromic film was used for dosimetry of sm...

متن کامل

Dosimetric evaluation of a treatment planning system using pencil beam convolution algorithm for enhanced dynamic wedges with symmetric and asymmetric fields

Background: The dosimetric performance of Eclipse 6.5 three dimensional treatment planning system (3DTPS) is evaluated by comparing the calculated and measured dose in two dimensions following the guide lines of American Association for Physicists in Medicine Task Group 53. Materials and Methods: The calculations were performed by the 3DTPS for symmetric as well as asymmetric fields for standar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 8  شماره 

صفحات  -

تاریخ انتشار 2012