A comparison of the effect of 3M Fresnel prisms and Trusetal prism foils on visual function
نویسندگان
چکیده
Aim: To determine any differences in visual acuity (VA) and contrast sensitivity (CS) between 3M Fresnel prisms and Trusetal prisms foils. Methods: Sixteen participants (mean age 20 years) with normal VA and CS participated. The effect of 5D, 10D, 20D and 30D prism strengths on monocular VA and CS was assessed using a Bailey-Lovie logMAR chart and Pelli-Robson chart, respectively. Measurements were carried out for both 3M Fresnel prisms and Trusetal prism foils. A comparison of the physical properties of the two prism types was made. Results: Deterioration in VA and CS was evident with increasing prism strength with both prism types. VA was more significantly reduced with 3M Fresnel prisms than with Trusetal prism foils [F1,15 = 19.63, p< 0.001]. There was significant interaction between prism types and prism strength [F3,45 = 10.36, p< 0.0001], due to 30D 3M Fresnel prisms reducing VA by 0.13 logMAR more than the Trusetal prism foils. There was no statistically significant difference between the prism types for CS [F1,15 = 2.21, p = 0.1582]. 3M Fresnel prisms were thinner than the Trusetal prism foils. The thicker Trusetal prism foils consist of fewer bases per centimetre but were more difficult to fit to spectacle lenses. Conclusions: There is no difference in VA or CS regardless of whether a 3M Fresnel prism or Trusetal prism foil is used until 30D, when Trusetal prism foils give better VA. For large deviations it may therefore be more beneficial for the patient to use a Trusetal prism as part of their treatment plan.
منابع مشابه
The Prismatic Effect on Stereoacuity in Intermittent Exotropia
PURPOSE To evaluate the effect of acrylic refractive prism and Fresnel membrane prism on stereoacuity in intermittent exotropia. MATERIALS AND METHODS Stereoacuities of fifty-two patients (mean age, 12.4 years; range 6 to 45 years) with intermittent exotropia were measured using the Titmus and TNO stereotests, while they wore prisms of varying power on nonfixating eye or evenly on each eye. ...
متن کاملImpact of high power and angle of incidence on prism corrections for visual field loss.
Prism distortions and spurious reflections are not usually considered when prescribing prisms to compensate for visual field loss due to homonymous hemianopia. Distortions and reflections in the high power Fresnel prisms used in peripheral prism placement can be considerable, and the simplifying assumption that prism deflection power is independent of angle of incidence into the prisms results ...
متن کاملMultiplexing Prisms for Field Expansion.
PURPOSE Prisms used for field expansion are limited by the optical scotoma at a prism apex (apical scotoma). For a patient with two functioning eyes, fitting prisms unilaterally allows the other eye to compensate for the apical scotoma. A monocular patient's field loss cannot be expanded with a conventional or Fresnel prism because of the apical scotoma. A newly invented optical device, the mul...
متن کاملHigh-Power Prismatic Devices for Oblique Peripheral Prisms
PURPOSE Horizontal peripheral prisms for hemianopia provide field expansion above and below the horizontal meridian; however, there is a vertical gap leaving the central area (important for driving) without expansion. In the oblique design, tilting the bases of both prism segments toward the horizontal meridian moves the field expansion area vertically and centrally (closing the central gap) wh...
متن کاملارزیابی تغییرات دید عمق دور افراد نرمال در اثر هتروفوریای ایجاد شده بهوسیلهی تست سه میله
Backgrounds and Objective: Stereoacuity is due to a relative difference between images because of retinal disparity. Measurment of stereoacuity is important for diagnosis and treatment of binocular anomalies and noerological problems. The aim of this study was to determine the effect of induced heterophoria by base-out and base-in prisms on distance stereopsis by the Three Needle Test. Material...