Objective To evaluate transportation (T) and centering ability (CA) of root canal preparations using continuous or reciprocating nickel-titanium endodontic files. Materials and Methods Ninety-six mesiobuccal root canals of mandibular first and second molars were randomly divided into 6 groups (n=16) according to the rotary file used: 1. ProTaper Next; 2. ProTaper Gold; 3. Mtwo; 4. BioRaCe; 5. WaveOne Gold; 6. Reciproc. Root canals were prepared according to manufacturer's instructions. Cone beam computed tomography scans were obtained before and after root canal preparation. Measurements were made at six different reference points: 2, 3 and 4 mm from the apex and 2, 3 and 4 mm below furcation in different directions. Results The greatest Mesiodistal (MD) Transportation (T) was found for Reciproc files (p<0.05), and the greatest buccolingual (BL) T, for Reciproc, ProTaper Gold and ProTaper Next files (p<0.05). The greatest Mesiodistal (MD) Centering Ability (CA) was found for BioRaCe files (p<0.05), and the greatest Buccolingual (BL) CA, for BioRaCe and Mtwo files (p<0.05). Conclusion All systems produced root canal transportation. No file system achieved perfect CA of root preparation. Reciproc files had the greatest MD T and BL T. BioRaCe files had the greatest MD CA, whereas BL CA was similar for BioRaCe and Mtwo files.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lifespan of one nickel-titanium rotary file with reciprocating motion in curved root canals.

INTRODUCTION The purpose of this study was to examine the lifespan of one nickel-titanium (NiTi) rotary file when used in reciprocating motion and to compare the time required for its preparation of a curved root canal using both reciprocating and continuous motion. METHODS One hundred twenty curved canals from 60 extracted maxillary and mandibular molars were selected for measuring the mean ...

متن کامل

Safe root canal preparation using reciprocating nickel-titanium instruments

253 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/ by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. Safe root canal preparation using reciprocating nickel-titanium instruments Readers' forum

متن کامل

TF TM Adaptive : a novel approach to nickel - titanium instrumentation

instruments have been traditionally used with a continuous rotary motion, but more recently, a new approach to the use of nickel-titanium instruments in a reciprocating movement has been introduced by Yared (2004). The clockwise (CW) and counter-clockwise (CCW) rotations used by Yared were four-tenths and two-tenths of a circle respectively, and the rotational speed utilized was 400 rpm. The co...

متن کامل

The instrument-centering ability of four Nickel-Titanium instruments in simulated curved root canals

The aim of root canal preparation is to clean and shape the root canal system while maintaining the original configuration. However, traditional hand instruments often failed in achieving these objectives, especially when used in severely curved canals. Over the years, many nickel-titanium rotary instruments have been developed to improve root canal preparation. More flexible files made of nick...

متن کامل

Comparison of the shaping ability of RaCe, FlexMaster, and ProFile nickel-titanium instruments in severely curved root canals

BACKGROUND This in vitro study compared the shaping ability of RaCe, FlexMaster, and ProFile rotary nickel-titanium instruments in severely curved root canals of extracted teeth. MATERIAL AND METHODS Sixty maxillary molars with curvatures ranging from 25° to 65° were embedded in a muffle system and portioned into five horizontal sections (thickness 1.2 mm), starting from the apex. Canals were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2018