A Study on Biocompatibility of Three Endodontic Sealers: Intensity and Duration of Tissue Irritation
نویسندگان
چکیده
INTRODUCTION Several studies have evaluated the inflammatory reaction triggered by Epiphany (EPH), a contemporary endodontic sealer. However, they used conventional parameters, which need additional analysis to better understand the reactions induced by this sealer compared to other traditional sealers. METHODS AND MATERIALS The intensity and time span of tissue irritations for three endodontic sealers were assessed by inflammatory reactions, fibrous capsule measurement and mast cell counts. Tubes containing freshly mixed EPH, AH plus (AHP) and Endofill (ENF) were subcutaneously implanted into the backs of 28 Wistar rats. The side wall of the tube was used as the control. At 14, 21, 42 and 60 days, the connective tissue surrounding the implants (n=7) was stained for histopathological analysis. The Friedman test was applied to compare the results. The level of significance was set at 0.05. RESULTS At days 14 and 21, a significant difference among the groups was observed, with the ENF showing the worst tissue response (P<0.001). ENF remained the most aggressive sealer at 42 and 60 days, compared with EPH (P<0.05). No differences were found for the fibrous capsule thicknesses among the groups in each period. The number of mast cells per field did not show difference among the sealers at 21 and 60 days. CONCLUSIONS EPH and AHP elicited similar patterns of irritation, as demonstrated by the inflammatory scores and fibrous capsule thicknesses. ENF caused the highest degree of tissue damage. The increase in mast cell counts observed during the early and late periods shows the possibility of late hypersensitivity to the test materials.
منابع مشابه
Biocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model
Biocompatibility comparison of two different sealers AH26 and Apexit: In-vivo animal model Dr. Zare Jahromi, M.* - Dr. Razavi, S.M.** - Dr. Tabesh, B.*** *Assistant Professor of Endodontics Dept., Faculty of Dentistry, Isfahan Azad University (Khorasgan). **Assistant Professor of Pathology Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ***Dentist. Abstract Background & Aim...
متن کاملHistopathologic Evaluation of the Subcutaneous Tissue Response to Three Endodontic Sealers
Introduction: The materials used for obturation of root canal system may be extruded through apical foramen into the periapical tissue. Therefore, biocompatibility of these materials is very important. The purpose of this study was to evaluate the in vivo biocompatibility of three conventional endodontic sealers: AH26, Roth 801, and ZOE after their subcutaneous implantation in rats. Methods: Tw...
متن کاملAntimicrobial activity of three different endodontic sealers on the enterococcus faecalis and lactobacillus (in vitro)
Introduction: Growth and proliferation of the remaining microorganisms within the root canals may destroy the surrounding tissue of the root and leads to periapical lesion. Consequently, the complete elimination of microorganisms from the root canal is a n important goal of endodontic therapy. Endodontic sealers do not provide complete seal in root canal system, and micro spaces have always rem...
متن کاملSubcutaneous Connective Tissue Reaction to a New Nano Zinc-Oxide Eugenol Sealer in Rat Model
INTRODUCTION The aim of this animal study was to evaluate the histological response of the new nano zinc-oxide eugenol (NZOE) sealer in comparison with Pulp Canal Sealer (ZOE based) and AH-26 (epoxy resin sealer). METHODS AND MATERIALS A total of 27 Wistar rats were used. Four polyethylene tubes were implanted in the back of each rat (three tubes containing the test materials and an empty tub...
متن کاملEvaluation of the Biocompatibility of Root Canal Sealers Using Subcutaneous Implants
The purpose of this study was to evaluate in vivo the biocompatibility of Endométhasone, Pulp Canal Sealer EWT and AH-Plus root canal sealers after implantation in rat connective tissue. Twenty-four Wistar-Furth rats were used. Polyethylene tubes were filled with the sealers and implanted into specific dorsal subdermal tissue sites of the rats. Implants were removed after 3, 7 and 30 days, fixe...
متن کاملذخیره در منابع من