Gamma ray transmission imaging detectors using a double gap resistive plate chamber

نویسندگان

  • S. Park
  • S. H. Ahn
  • B. Hong
  • S. J. Hong
  • T. I. Kang
  • T. J. Kim
  • K. S. Lee
  • J. K. Lim
  • D. H. Moon
  • J. K. Oh
  • W. J. Park
  • M. S. Ryu
  • K. S. Sim
چکیده

In this paper we report a feasibility study of the gamma ray transmission imaging using a double gap resistive plate chamber. The detector consists of two layers of 2 mm resistive plate chamber (RPC) gaps with two-dimensional read-out strips of 10 mm pitch. Gamma ray transmission images for objects inside a cabinet, using a 10 mCi 137 Cs isotope, were obtained with a pixel resolution of 5 Â 5 mm 2. RPC sensitivities for various gamma ray energies were evaluated by the GEANT-based simulations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study on the operational conditions of a double-gap resistive plate chamber for the CMS

We present the results from cosmic ray tests on the forward Resistive Plate Chamber (RPC) for the CMS. Double-gap prototype RPC were built and tested in the Korea Detector Laboratory (KODEL). We found that addition of SF 6 and water vapor to the tetra#uorethane-based gas mixture was required for the long-term stable operation of RPC. E$ciency, time resolution as well as cross-talk behavior of t...

متن کامل

Cosmic ray test results on resistive plate chamber for the BESIII experiments

A cosmic ray test system has been built to fully qualify the resistive plate chambers for the MUON system of the BESIII experiment. The setup has been designed to measure detector’s performance and to verify the stability and reliability of the MUON system. The same electronics, similar readout method and data analysis for BESIII MUON system have been used for this station. With this station, t...

متن کامل

Characteristics of a double gap resistive plate chamber for the endcap region of CMS/LHC: data vs. simulation in avalanche mode

We present the detailed analysis of the time and charge signals of a prototype double gap resistive plate chamber for the endcap region of the compact muon solenoid detector at CERN LHC. We demonstrate that the operating highvoltage plateau can be extended at least up to 400V with the present design. The simple avalanche multiplication model can reproduce the experimental charge spectra reasona...

متن کامل

GEANT4 code for Simulation of neutrons for a double- gap Resistive Plate Chamber

GEANT4 is a toolkit for simulating the passage of particles though matter, which contains a complete range of functionality including tracking, geometry, physics models, and hits. In this article, an attempt to use GEANT4 Monte Carlo code to watch a double-gap Resistive Plate Chamber's (RPC) response to neutrons is presented. The simulation calculations of the double-gap RPC have been evaluated...

متن کامل

Development of TOF-PET detectors based on the Multi-Gap Resistive Plate Chambers

We describe the development, construction and preliminary results obtained with medium-size MultiGap Resistive Plate Chambers prototypes designed to detect and localize 511 keV photons for Positron Emission Tomography imaging applications. The devices are intended for in-beam monitoring of the treatment plans throughout deep tumor therapy with hadron beams; emphasis is put on achieving coincide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004