Patient dosimetry in diagnostic and interventional radiology: a practical approach using trigger levels.
نویسندگان
چکیده
Patient dosimetry is performed in radiology and interventional radiology to assess whether deterministic injuries may occur and to establish the risk of stochastic effects. A fundamental problem for patient dosimetry is that no single quantity can be used to accurately assess both the risk of stochastic effects and whether deterministic injuries will occur following a specific examination or procedure. In cardiology and interventional radiology, two different approaches to patient dosimetry are commonly used. Effective dose is a quantity which correlates reasonably well with the risk of stochastic effects. Effective dose may be deduced from the dose-area product (DAP) for the procedure if sufficient information is known. DAP does not correlate with maximum skin dose, which may be used to predict whether deterministic injuries may occur. DAP meter readings may be used as a trigger level for the investigation of maximum skin entrance dose. Trigger levels for different procedures are proposed.
منابع مشابه
Assessment of patient entrance skin dose (ESD) and effective dose (ED) for the most common interventional radiological exams at Mazandaran hospital
Introduction: Nowadays we are witnessing an exponential application of interventional radiology techniques in various communities as well as Iran. Radiological technique is regarded as the 2nd contributing factor in increasing the amount of public doses in various societies. So that related radiation protection organization has recommended measuring patient d...
متن کاملResponse to 'Patient dose measurements in radiological practices'.
A lack of suitable dosimetric quantities for application in diagnostic radiology is noted by Dr Moores. It is concluded by Dr Moores that it is not possible to adhere to the basic principles of the International Commission on Radiation Units and Measurements (ICRU) regarding patient dosimetry in diagnostic radiology due to the extremely wide variety of quantities and units employed. The conclus...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...
متن کاملAdult reference levels in diagnostic and interventional radiology for temporary use in Switzerland.
This work aims at establishing a set of diagnostic reference levels (DRLs) for various types of examinations performed in diagnostic and interventional radiology. The average doses for 257 types of radiological examinations were established during the 1998 nationwide survey on the exposure of the Swiss population by radiodiagnostics. They were calculated using appropriate dosimetric models and ...
متن کاملارزیابی دز ورودی پوستی و دز مؤثر بیماران در معمول ترین آزمون های رادیولوژی
Introduction: Nowadays, we are witnessing a progressive application of radiology techniques in various communities as well as in Iran. Medical radiological examinations are one of the important sources of public radiological dose. Entrance skin doses and effective doses for patients in diagnostic radiology examinations should be assessed for the imaging techniques optimization and patient&rsquo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 117 1-3 شماره
صفحات -
تاریخ انتشار 2005