Erythrocyte lysis in isotonic solution of ammonium chloride: theoretical modeling and experimental verification.

نویسندگان

  • Andrey V Chernyshev
  • Peter A Tarasov
  • Konstantin A Semianov
  • Vyacheslav M Nekrasov
  • Alfons G Hoekstra
  • Valeri P Maltsev
چکیده

A mathematical model of erythrocyte lysis in isotonic solution of ammonium chloride is presented in frames of a statistical approach. The model is used to evaluate several parameters of mature erythrocytes (volume, surface area, hemoglobin concentration, number of anionic exchangers on membrane, elasticity and critical tension of membrane) through their sphering and lysis measured by a scanning flow cytometer (SFC). SFC allows measuring the light-scattering pattern (indicatrix) of an individual cell over the angular range from 10 degrees to 60 degrees . Comparison of the experimentally measured and theoretically calculated light scattering patterns allows discrimination of spherical from non-spherical erythrocytes and evaluation of volume and hemoglobin concentration for individual spherical cells. Three different processes were applied for erythrocytes sphering: (1) colloid osmotic lysis in isotonic solution of ammonium chloride, (2) isovolumetric sphering in the presence of sodium dodecyl sulphate and albumin in neutrally buffered isotonic saline, and (3) osmotic fragility test in hypotonic media. For the hemolysis in ammonium chloride, the evolution of distributions of sphered erythrocytes on volume and hemoglobin content was monitored in real-time experiments. The analysis of experimental data was performed in the context of a statistical approach, taking into account that parameters of erythrocytes vary from cell to cell.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erythrocyte stability in ethanol-saline solutions.

Sir,—In a clinical evaluation of ethanol as an anaesthetic agent, Isaac and Dundee (1969) and Dundee and coworkers (1970) established that 8% w/v (10% v/v) ethanol in Hartmann's solution was the most satisfactory concentration for i.v. infusion in man and was associated with a low frequency of thrombophlebitis. Sanderson and co-workers (1970) confirmed that in vitro ethanol solutions in concent...

متن کامل

Physical and theoretical modeling of rock slopes against block-flexure toppling failure

Block-flexure is the most common mode of toppling failure in natural and excavated rock slopes. In such failure, some rock blocks break due to tensile stresses and some overturn under their own weights and then all of them topple together. In this paper, first, a brief review of previous studies on toppling failures is presented. Then, the physical and mechanical properties of experimental mode...

متن کامل

The effect of subarachnoid erythrocyte lysate on brain injury: a preliminary study

Abundant erythrocytes remain and lyse partially in the subarachnoid space after severe subarachnoid haemorrhage (SAH). But the effect of subarachnoid erythrocyte lysate on brain injury is still not completely clear. In this study, autologous erythrocytes (the non-lysate group) and their lysate (the lysate group) were injected separately into the cistern magna of rabbits to induce a model of exp...

متن کامل

Protective Effect of Rosmarinus officinalis L. Essential Oil against Free Radical-Induced Erythrocyte Lysis

       The oxidative hemolysis of rat erythrocytes induced by 2,2’-azobis–(2-amidinopropane) (AAPH) and its inhibition by rosemary essential oil was studied. Different concentrations (0.178, 0.357, 0.534 and 0.712 ml/ml) of the essential oil showed no significant hemolysis compared to phosphate buffer solution. AAPH (25 mM and 50 mM) induced hemolysis in a time-dependent manner. Diff e r e n t ...

متن کامل

Adaptation of red blood cell lysis represents a fundamental breakthrough that improves the sensitivity of Salmonella detection in blood

AIMS Isolation of Salmonella Typhi from blood culture is the standard diagnostic for confirming typhoid fever but it is unavailable in many developing countries. We previously described a Microwave Accelerated Metal Enhanced Fluorescence (MAMEF)-based assay to detect Salmonella in medium. Attempts to detect Salmonella in blood were unsuccessful, presumably due to the interference of erythrocyte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of theoretical biology

دوره 251 1  شماره 

صفحات  -

تاریخ انتشار 2008