Determination of the resistance across incompressible strips through imaging of charge motion

نویسندگان

  • P. I. Glicofridis
  • G. Finkelstein
  • R. C. Ashoori
  • M. Shayegan
چکیده

Using charge-accumulation imaging, we measure the charge flow across an incompressible strip and follow its evolution with magnetic field. The strip runs parallel to the edge of a gate deposited on the sample and forms at positions where an exact number of integer Landau levels is filled. An RC model of charging fits the data well and enables us to determine the resistance across the strip. Surprisingly, we find that the strip becomes more resistive as its width decreases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling subsurface charge accumulation images of a quantum Hall liquid

Subsurface charge accumulation imaging is a cryogenic scanning probe technique that has recently been used to spatially probe incompressible strips formed in a two-dimensional electron system ~2DES! at high magnetic fields. In this paper, we present a detailed numerical modeling of these data. At a basic level, the method produces results that agree well with the predictions of models based on ...

متن کامل

PULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW

Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...

متن کامل

Development of Double-Sided Microstructured Si(Li) Detectors

A new technique for manufacturing double-sided structured Si(Li) detectors has been established. The position-sensitive structure on the implanted p–contact can be made smaller than 100 m by photolithography followed by plasma etching of grooves to separate the position elements. By modifying this technique position-sensitive structures on a thin ( 30 m) Li-diffused contact were created. Areas ...

متن کامل

Determination of Trimethoprim Based on Charge-Transfer Complexes Formation

A spectrophotometric study concerning the interaction between Trimethoprim (TMP) ,Sulfamethoxazole (SFMx), as n-donor and 2,3-dichloro-5,6- dicyano-P-benzoquinine (DDQ) and chloranilic acid (CA) as π-acceptor were been performed at 25°C. The results of interaction of CA and DDQwith TMP indicate the formation of a 1:1, 1:2, charge transfer complexes through non equilibrium reactions. In the case...

متن کامل

اصلاح حرکت در تصویربرداری اسپکت میوکارد با استفاده از مدل‌سازی منحنی چند جمله ای

Background and purpose: Patient motion during myocardial perfusion SPECT can produce artifacts in reconstructed images which might affect clinical diagnosis. This paper attempts to present a new approach for the detection and correction of cardiac motion utilizing the data obtained during the imaging process. Materials and methods: Our method quantifies motion through polynomial curves modelin...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002