The Effect of Different Powers of Er:YAG Laser Treatment on Surface Morphology of an Indirect Composite Resin: SEM Evaluation.

نویسندگان

  • Nazanin Zeinab Garshasbzadeh
  • Mansoreh Mirzaie
  • Esmael Yassini
  • Sima Shahabi
  • Nasim Chiniforush
چکیده

INTRODUCTION Indirect composites are developed to overcome the shortcomings of direct composites but, the adhesion of resin cements to indirect composites is still difficult. The purpose of this study was to evaluate the surface morphology of indirect resin composite treated by different powers of Er:YAG laser using Scanning Electron Microscopy (SEM). METHODS indirect resin composite blocks (GC Gradia DA2, Japan) with 15× 10 × 10 mm dimensions were made according to manufacturer's instructions (n=7). The bonding surface of these blocks were polished, then the samples were divided to seven groups as follow: Erbium-Doped Yttrium Aluminum Garnet (Er:YAG)laser with output power of 2, 3, 4, 5, 6,7 W (frequency of 20 Hz, very short pulse) and no treatment. Then, the surfaces were evaluated by scanning electron microscope. RESULTS The surface treated by Er:YAG laser showed a porous surface. But the amount and pattern of these irregularities differ in each group which may produce micromechanical retention compared to control group with no treatment. CONCLUSION Er:YAG laser can be used as an alternative technique for surface treatment and roughening of indirect resin composites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Laser Treatment on Surface Morphology of Indirect Composite Resin: Scanning Electron Microscope (SEM) Evaluation.

INTRODUCTION The aim of this study was to evaluate and compare the Scanning electron microscope (SEM) of indirect composite conditioned by Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser, Neodymium-Doped Yttrium Aluminium Garnet (Nd:YAG) laser and Carbon Dioxide (CO2) laser. METHODS 18 indirect composite blocks (GC Gradia DA2, Japan) with 15 × 10 × 10 mm dimensions were made. The bonding ...

متن کامل

بررسی اثر آماده سازی سطح یک نوع کامپوزیت غیرمستقیم، به وسیله دو نوع لیزرNd:YAG و Er:YAG و اسید اچ، بر استحکام باند ریز برشی سمان رزینی

Introduction: In order to increase the bonding strength of the composite resin cements to the indirect composites, experiments such as the creation of surface roughness with sandblasting, acid-etching, silane application, laser, etc. have been carried out. However, there is no consensus about the results. Therefore, the purpose of this study was to investigate the effect of Er: YAG and Nd: YAG ...

متن کامل

Scanning Electron Microscope (SEM) Evaluation of Composite Surface Irradiated by Different Powers of Er:YAG Laser.

INTRODUCTION The aim of this study was to evaluate the composite surface treated by different powers of Erbium-Doped Yttrium Aluminum Garnet (Er:YAG) laser in comparison with bur preparation via scanning electron microscope. METHODS Fourteen composite resin blocks with 15× 10 × 10 mm dimensions were used in this study. The samples were divided to seven groups as follow: Group 1 (power: 1 W, E...

متن کامل

Microleakage of cervical cavities prepared by an Er:YAG laser or a high-speed handpiece, after restoration using resin composite

Objectives: The purpose of this in vitro study was to evaluate the microleakage of cervical cavities prepared by Er:YAG laser or high-speed hand piece and bur. Methods: This in vitro experimental study was performed on 40 sound permanent third molar teeth randomly assigned into two equal groups (n=20). In the first group, high-speed hand piece and bur and in the second group Er:YAG la...

متن کامل

Amalgam Surface Treatment by Different Output Powers of Er:YAG Laser:SEM Evaluation.

INTRODUCTION The purpose of this study was to evaluate amalgam surfaces treated by different output powers of erbium-doped yttrium aluminum garnet (Er:YAG) laser by scanning electron microscope (SEM). METHODS Twenty-one amalgam blocks (8 mm × 8 mm, 3 mm thickness) were prepared by condensing silver amalgam (into putty impression material. After keeping them for 24 hours in distilled water, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of lasers in medical sciences

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2014