Comparison between percutaneous and traditional fixation of lumbar spine fracture: intraoperative radiation exposure levels and outcomes.

نویسندگان

  • N Bronsard
  • T Boli
  • M Challali
  • R de Dompsure
  • N Amoretti
  • B Padovani
  • G Bruneton
  • A Fuchs
  • F de Peretti
چکیده

OBJECTIVE To compare radiation exposure doses and clinical and radiological outcomes between percutaneous pedicular screwing (closed reduction internal fixation [CRIF]) and classical open reduction internal fixation (ORIF) in lumbar spine fracture without neurologic deficit. MATERIALS AND METHODS Sixty patients (mean age, 42.5 years) were divided into two treatment groups: (Percutaneous) CRIF versus (traditional) ORIF. Screw position and anatomic vertebral reconstruction were checked on routine control X-ray and postoperative CT scan. Study parameters comprised: surgery time, radiation exposure time, radiation dose level for X-ray (DAP) and for CT (DLP),blood loss, length of hospital stay and postoperative pain (VAS). RESULTS At a mean 25.5 months' follow-up,there were no significant inter-group differences on the epidemiological parameters: age, gender, fracture level, fracture type on the Magerl classification, preoperative local vertebral kyphosis angle, or fracture-to-surgery interval. Effective radiation dose was 3-fold higher in CRIF than in ORIF, but 6-fold lower than for the postoperative CT scan. Postoperative pain on VAS was significantly lower after CRIF, allowing earlier gait resumption and return to work and daily activity. There were no significant differences in length of hospital stay, patient satisfaction, screw malpositioning or postoperative or end-of-follow-up kyphosis angle. CONCLUSION Percutaneous surgery provided clinical and radiological outcomes strictly comparable to those of open surgery, but with a higher effective radiation exposure dose, including for the medical team and especially for the surgeon. This higher exposure dose, however, is to be relativized by comparison to that of the postoperative CT scan, which involved a much higher exposure dose for the patient. LEVEL OF EVIDENCE Level IV. Retrospective study.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique

Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...

متن کامل

One-stage extreme lateral interbody fusion and percutaneous pedicle screw fixation in lumbar spine tuberculosis

OBJECTIVES We explored the efficacy of minimal invasive surgery including one-stage debridement and intervertebral fusion through extreme lateral channel (XLIF) combined with lateral or percutaneous posterior pedicle screw fixation for the treatment of lumbar spine tuberculosis. METHODS Twenty two patients with lumbar tuberculosis who underwent surgery with XLIF technique and internal fixatio...

متن کامل

Intraoperative Computed Tomography Navigation for Transpedicular Screw Fixation to Treat Unstable Thoracic and Lumbar Spine Fractures

Transpedicular screw (TPS) fixation in unstable thoracic and lumbar (TL) spine fractures remains technically difficult because of destroyed anatomical landmarks, unstable gross segments, and discrepancies in anatomic orientation using conventional anatomic landmarks, fluoroscopic guidance, or computed tomography (CT)-based navigation. In this study, we evaluated the safety and accuracy of TPS p...

متن کامل

Electromagnetic Navigation in Minimally Invasive Spine Surgery: Results of a Cadaveric Study to Evaluate Percutaneous Pedicle Screw Insertion

BACKGROUND This cadaveric study compared efficacy and safety of an electromagnetic (EM) guidance system versus conventional fluoroscopy for percutaneous pedicle screw fixation. As percutaneous pedicle screw fixation becomes increasingly common in spinal surgery, intraoperative imaging systems that maximize efficiency while minimizing radiation exposure and inaccurate trajectories will be progre...

متن کامل

Open versus Percutaneous Stabilization of Thoracolumbar Spine Fractures: A Short-Term Functional and Radiological Follow-up.

PURPOSE OF THE STUDY A prospective cohort study evaluates the functional and radiological outcome of thoracolumbar spine fractures treated either with open or percutaneous dorsal instrumentation. In recent years, several studies advocate percutaneous stabilization of spinal fractures in patients without neurological deficits. However, it is still debated whether percutaneous stabilization is su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 99 2  شماره 

صفحات  -

تاریخ انتشار 2013