Comfort and vision scores at insertion and removal during 1 month of wear of Paragon CRT for corneal reshaping.
نویسندگان
چکیده
PURPOSE The goal of this study was to evaluate the pattern of initial adaptation of neophytes to corneal refractive therapy (CRT) for overnight corneal reshaping in terms of comfort and subjective visual performance at lens insertion at night and lens removal in the morning. METHODS Twenty-two young healthy subjects were enrolled in this study. All of them had been trialed to assess adaptation to conventional alignment-fit rigid gas permeable lenses and were only enrolled in this study after a 2-week wash-out period. Visual analog scales for subjective comfort and vision were recorded on a form given to the patient on days 1, 2, 3, 5, 7, 14, 21, and 28. Additionally, the patient attended the clinic on days 1, 7, 15, and 30 after fitting, for follow-up. RESULTS Successful adaptation was obtained in 21 of the 22 initially enrolled individuals. The average overnight wearing time remained constant during the study at 8 hrs per day. Overall comfort rates increased significantly up to values of 8.02 and 9.12 out of 10 at insertion and removal, respectively (P<0.001). Subjective vision scores also increased significantly at the end of the 1-month study period (P<0.001). CONCLUSIONS Adaptation to CRT is rapid in terms of subjective comfort and vision. Comfort significantly increases by day 5, whereas subjective vision in the morning reaches its maximum by days 15 to 21 and at the end of the day by days 10 to 15. These results are of interest to clinicians to provide evidence-based information to their patients about the expected time to adapt to CRT in terms of self-reported comfort and vision.
منابع مشابه
A comparison of multipurpose and conventional 2-step rigid gas-permeable solutions with Paragon corneal refractive therapy lenses.
PURPOSE This investigation compared 2 commonly used care systems, Boston Advance(R) care system and Boston Simplus (Bausch & Lomb, Rochester, New York) multipurpose solution, and the effects of these solutions on unaided daytime vision, care, and handling and comfort with Paragon corneal refractive therapy (CRT)(R) (Paragon Vision Sciences, Mesa, Arizona) lenses. METHODS Eighteen subjects wea...
متن کاملThe Children's Overnight Orthokeratology Investigation (COOKI) pilot study.
PURPOSE Innovations in contact lens materials and designs allow patients to wear contact lenses during sleep to flatten the cornea and temporarily to reduce myopic refractive error and improve unaided visual acuity. We conducted the Children's Overnight Orthokeratology Investigation (COOKI) pilot study, a case series, to describe the refractive error and visual changes, as well as the slitlamp ...
متن کاملOvernight corneal reshaping versus soft disposable contact lenses: vision-related quality-of-life differences from a randomized clinical trial.
PURPOSE The purpose of this article is to evaluate patients' visual acuity, symptoms, and perceptions of vision-related quality of life in a randomized crossover clinical trial of overnight corneal reshaping (OCR) and daily wear soft lenses (SCL). METHODS Qualified subjects were randomly assigned to wear one mode of contact lens for 8 weeks and then, after a washout period, they wore the alte...
متن کاملCorneal ulcers in two children wearing paragon corneal refractive therapy lenses.
OBJECTIVES To report the development of corneal ulcers in two children wearing Paragon Corneal Refractive Therapy (CRT) lenses. METHODS Two case reports of children who developed corneal ulcers when fit with Paragon CRT contact lenses, which were worn nightly, are discussed. Each patient presented with a bacterial corneal ulcer after wearing CRT contact lenses for less than 6 months. In the f...
متن کاملClinical performance of KeraSoft® IC in irregular corneas
PURPOSE This study evaluated the clinical performance of KeraSoft(®) IC (KIC) soft contact lenses in subjects with irregular corneas. PATIENTS AND METHODS This was a 12-month, prospective, open-label, observational study, which enrolled 43 subjects who were 18 years of age or older with irregular corneas. Subjects were fit according to the KIC Fitting Manual (kerasoftic.com). After achieving ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eye & contact lens
دوره 37 5 شماره
صفحات -
تاریخ انتشار 2011